4. Tamper switch: The tamper switch is used to check whether the box of host be opened or not, if so it will send out a
relevant report.
5. Backup A/D: There is still 1 A/D input interface for potential use.
VII. WIRELESS ACCESSORIES DESCRIPTION
The TLU100N has now 3 kinds wireless equipments: wireless door sensor, wireless temperature sensor and wireless key
pad.
1. Wireless Door magnetic sensor
A: The unit can support up to 4 wireless magnetic door sensors. The door sensor can monitor the door status and will
send out the changed message timely. It has 5 kinds of report: Door open or Door close, Tamper switch pop and
Tamper switch push, Low battery report, It will send a message to host as soon as its tamper switch or magnetic
door status changed. It will also send a low battery message to host when its voltage below 2.3v.
B: The sensor ID will be sent to host every 30 seconds after power on in the first 3 minutes, user should power on
the sensor device no sooner than the wireless door sensor ID learning function of TLU100N has been launched.
2. Wireless Temperature sensor
A: The temperature will report its environmental temperature and then send it to host. In order to save energy and fit
for the actual application environment too, the temperature will be hand to host every a fixed centigrade changed.
This sensor has 5 kinds of reports: Tamper switch pop and Tamper switch push, Out of temperature scope and
Enter the temperature scope, Low battery report, It will send a message to host as soon as its tamper switch status
changed. It will also send a low battery message to host when its voltage below 5v.
B: The sensor ID will be sent to host every 30 seconds after power on in the first 3 minutes, user should power on
the sensor device no sooner than the wireless temperature sensor ID learning function of TLU100N has been
launched.
C: The sensor will report its current temperature to host every fixed centigrade temperature changed, this fixed
reference value can be defined by the on board 3 jumpers. The following jumper code table and the jumper graph
describe how to set the fixed interval for temperature value handing in.
Jumper Code Description
C B A When will the sensor hand in its update temperature value to host ?
on on on
Current temperature will send to host every 8℃ changed
on on off
Current temperature will send to host every 7℃ changed
on off on
Current temperature will send to host every 6℃ changed
on off off
Current temperature will send to host every 5℃ changed
off on on
Current temperature will send to host every 4℃ changed
off on off
Current temperature will send to host every 3℃ changed
off off on
Current temperature will send to host every 2℃ changed
off off off
Current temperature will send to host every 1℃ changed
Battery
A
B
C
Jumper
LED
Tamper switch