User's Manual
10
Hold 4
for 2 sec.
Turn the chose function to the
Four setting and the main unit
will operate this indication
If success, siren chirp once, flash “SUC” for
3 times
If failure, siren chirp twice, flash “FAIL” for
3 times
Hold
5 for 2
sec.
Exit the function choosing mode
The siren will chirp 4 times to indicate that
the main unit already get out function
selection mode. Transmitter T35 also will
chirp 4 times, flash “SUC” for 3 times to
indicate the goods condition of
communication. At the same time, the LCD
returns to the normal status.
CANBUS FUNCTION
1. ARM IN +: This input wire is normally connected to the vehicle’s CANBUS
interface. The system will enter arming mode when it detected arming signal from
the CANBUS interface.
2. DISARM IN +: This input wire is normally connected to the vehicle’s CANBUS
interface. The system will enter disarming mode when it detected disarming signal
from the CANBUS interface.
3. Hood trigger -: This input wire is normally connected to the vehicle’s CANBUS
interface. The system will alarm in arming mode when it detected hood trigger
signal from the CANBUS interface.
4. Ignition input +: This input wire is normally connected to the vehicle’s CANBUS
interface. If it detected ignition trigger signal from the CANBUS interface, then the
system will alarm in arming mode, and the system will enter driving mode in
disarming mode.
5. Door trigger -: This input wire is normally connected to the vehicle’s CANBUS
interface. The system will alarm in arming mode when it detected door trigger
signal from the CANBUS interface.
6. Trunk trigger -: This input wire is normally connected to the vehicle’s CANBUS
interface. The system will alarm in arming mode when it detected trunk trigger
signal from the CANBUS interface.