User's Manual
25
J2-10. IGNITION CONTROL DOME LIGHT
Pre-set: the dome light will off when ignition turn from off to on position, the dome light
will illume (max: 30s) when ignition turn from on to off position.
Variable 1: the dome light will not illume when ignition turn from on to off position.
J2-11. CHANNEL 2 OUTPUT MODE SELECT
Pre-set: Momentary output: Anytime, within 3 seconds press button 4 once then press
button 2 once, CH2 will output-300 mA.
Variable1: Latched output: this selection will output a –300mA signal from the channel 2
output as soon as the channel 2 button is pressed and will continue until the button is
pressed again.
Variable2: Latched output/reset with ignition ON: this selection will output a –300mA
signal from the channel 2 output as soon as the channel 2 button is pressed but will reset or
stop when the ignition is turned ON.
Variable3: 30 seconds output: this selection will continue output a 30 seconds –300mA
signal from the channel 2 output as soon as the channel 2 button is pressed.
J2-12. CHANNEL 3 OUTPUT MODE SELECT
Pre-set: Momentary output: Anytime, within 3 seconds press button 4 once then press
button 3 once, CH3 will output-300 mA
Variable1: Latched output: this selection will output a –300mA signal from the channel 3
output as soon as the channel 3 button is pressed and will continue until the button is
pressed again.
Variable2: Latched output/reset with ignition ON: this selection will output a –300mA
signal from the channel 3 output as soon as the channel 3 button is pressed but will reset or
stop when the ignition is turned ON.
Variable3: 30 seconds output: this selection will continue output a 30 seconds –300mA
signal from the channel 3 output as soon as the channel 3 button is pressed.