Variable 3: output pulse after shutdown. The wire will provide a 1 seconds -300mA pulsed
ground output after the remote start unit shuts down. This output will occur regardless of
whether the circuit times out or is manually terminated. Typically this output will be used
to re-lock/re-arm the vehicle if the doors unlock automatically when the ignition circuit
transitions to off or the factory anti-theft system is disarmed.
J2-6. PROGRAMMABLE L4 OUTPUT SELECT
Pre-set: dome light output: when the system is alarming, the dome light ON as parking light.
When disarm, dome light will ON until ignition ON (max 30 seconds).
Variable1: channel 4 output.
Variable2: channel 4 output and disarm
Variable 3: status continuant output when remote start.
J2-8. TRUNK (CHANNEL 1) OUTPUT MODE SELECT
Pre-set: Momentary output: Anytime, press button 3 for 2sec. the CH1 will output-300mA
constantly. Until the button 3 of transmitter are released.
Variable1: Latched output: this selection will output a 300mA signal from the channel 1
output as soon as the channel 1 button is pressed and will continue until the button is
pressed again.
Variable2: Latched output/reset with ignition ON: this selection will output a 300mA
signal from the channel 1 output as soon as the channel 1 button is pressed but will reset or
stop when the ignition is turned ON.
Variable3: 30 seconds output: this selection will continue output a 30 seconds 300mA
signal from the channel 1 output as soon as the channel 1 button is pressed.
J2-9.HORN TIMING SETTING
Pre-set: If setting horn output, when the system is arm/disarm with horn honk, the horn
honk default timing is 10ms.
Variable1: the horn honk timing is 50ms.
Variable2: the horn honk timing is 20ms.
Variable3: the horn honk timing is 30ms.