PORTMAN SECURITY SYSTEMS, LTD TWO-WAY CAR ALARM Operation/ Installation Manual AM9600---T89/T53/RX04 10/20/2012 Version 1.
T53(One way) T89(Two way) 1 2 3 4 6 1 7 2 3 5 4 6 7 5 charge T89 (Two way) T53 (One way) Press button 1 once Press and hold button 1 for 2 sec. Press button 2 once Press and hold button 2 for 2 sec. Press and hold button 3 for 2 sec.
Press button 4 once then press button 1 within 3 sec. Press button 4 once then press button 3 within 3 sec. Press button 4 once then press button 4 within 3 sec. Press and hold button 4 for 2 sec. Active anti car hijacking Channel 2 output Anytime Channel 4 output Anytime Arm with bypass shock sensor Manual active ready mode Press button 3 + 4 once together Press button 5 once then press button 1 within 3 sec. Press button 5 once then press button 2 within 3 sec.
CANBUS FUNCTION 1. ARM IN +: This input wire is normally connected to the vehicle’s CANBUS interface. The system will enter arming mode when it detected arming signal from the CANBUS interface. 2. DISARM IN +: This input wire is normally connected to the vehicle’s CANBUS interface. The system will enter disarming mode when it detected disarming signal from the CANBUS interface. 3. Hood trigger -: This input wire is normally connected to the vehicle’s CANBUS interface.
PC SETUP FUNCTION When unit is in disarming & Door open status, Select the correct COM port number, and then set the following functions 4
Default: to use factory default setting Request: read out the setting in the current page. Apply: transfer the setting to unit in the current pages. Exit: exit PC-Setup program. BASIC CAR ALARM FUNCTION DESCRIPTION CODE LEARNING a. b. When in disarmed mode.
c. d. e. times, system will enter code-learning mode. Press any button on the transmitter, the siren will chirp accordingly for confirmation as soon as the transmitter is learned. For example, if the first transmitter is learned, the siren will chirp once. If the second transmitter is learned, the siren will chirp twice, etc… Up to 3 transmitters can be programmed. If one of the transmitters is programmed, the other transmitters must be reprogrammed within 8 seconds.
SILENT ARMING WITH BYPASSING SHOCK SENSOR a. b. In disarming state, press button 5 once then press button 3 once within 3 seconds. Parking light will flash once, the system is entry in silent armed mode, all sensors will be bypassed in this arming cycle. HIDDEN ALARM ARMING a. b. c. First press button 5 then press and hold button 1 for 2 seconds within 3 seconds Siren will chirp twice and parking light will flash twice, the system will entry in no alarm arming mode.
f. g. h. will sound continually. If the trunk is triggered, the unit will send the information to transmitter, piezo will continue sound. If the hood is triggered, the unit will send the information to transmitter, piezo will continue sound. The transmitter alarm display (icon flash and piezo sound) will continuously for 30 seconds (max), within 30 seconds, press button 1 or button 2 will stop alarm. DISARMING a. b. c. d. e. f. Press button 2.
SMART IMMOBILIZATION (SEE FUNCTION SELECTION J1-11) a. b. When ignition is turned to OFF for 2 min, if the alarm is not armed, the engine will be cut automatically and cannot be restarted. LED will be ON for 0.5 seconds and then OFF for 3 seconds, and circle. Exit auto-immobilization mode: when ignition OFF, press button 2 once, Or please perform OVERRIDE PROCEDURE. 2-STAGE SENSOR a. b. If car receives a light shock, siren will chirp five times and parking lights will flash once for warning purpose.
b. If the system is in arming at this time, the trunk trigger, ext sensor is by-pass till the channel output off. After 4 seconds, the system is in arm mode again. CHANNEL 2 OUTPUT (SEE FUNCTION SELECTION J2-4 /J2-11) a. b. Anytime, first press button 4 once then press button 2 once within 3 seconds will to remote channel 2 output (with 300mA negative output). If the system is in arming at this time, the trunk trigger, ext sensor is by-pass till the channel output off.
alarm status if the power is lost and then reconnected. VALET MODE a. b. c. d. e. f. The system is disarming, turn ignition ON, within 8 seconds press and hold valet switch 3 seconds or press button 5 twice within 3 seconds. LED will be constantly ON, the parking light will flash once. In VALET mode, siren will chirp once and parking lights will flash once when lock the door, and siren will chirp twice and parking lights will flash twice when unlock the door.
For MODE C, there is one way to enter anti carjacking: The above a way is available for mode C. WHEN THE SYSTEM ENTERS ANTI CARJACKING MODE a. b. c. From the beginning to 15 seconds, nothing happen. From 16 to 30 seconds, the LED will blink slowly. From 31 to 45 seconds, the LED will blink fast and the siren will chirp once per 2 seconds. d. Form 46 to 70 seconds, the LED will blink fast and the siren will chirp once per seconds. e.
c. d. e. When the LED flashes the 1st number of the 2-pin code, turn ignition OFF. Then turn back ON to wait for LED to flash the 2 nd number of the 2-pin code. When the LED flashes the2nd number of the 2-pin code, turn ignition OFF When complete, siren will sound 4 times and the parking lights will flash 4 times to indicate system override, which indicates that the system is disarmed. If LED flashes over 12 times, it means the program exits override procedure.
NOTE: The unit remote start defaults check mode is Voltage mode; before the system entry the RPM learning mode, user must connect the vehicle RPM wire to the unit and function selection must select the start check mode is RPM mode. TURBO MODE (SEE FUNCTION SELECTION J3-11) a. The turbo mode is used for protect the engine. b. Before the ignition is turned from ON to OFF (ignition must be ON more than 10 seconds), the engine will not shutdown immediately, but continue remain running for 3 minutes. c.
REMOTE START OPERATION Remote start activation: The following inputs will activate the Remote Start sequence and if a successful start enters the ‘RUN’ mode. Transmitter activation: the transmitter button 4 is press and hold 2 seconds when the ignition is OFF. REMOTE START ‘RUN’ MODE: The ‘RUN’ mode begins when the unit has recognized a successful start. a. RUN time: The unit will keep the engine running for a maximum of 10 minutes (5, 20,30min option) from the time of a successful start.
hour automatic start timer in feature programmable. When timer modes start successful.NOTE1: This feature cannot be activated when the ignition is ON or the unit is in the ‘RUN’ mode. NOTE2: 3 Unsuccessful starts attempts will count as 1 successful start. The unit will attempt to start again at the next Timer mode start interval. d. EXIT TIMER MODE: The following inputs & operations will cause the unit to exit the ‘TIMER’ mode. a. press button 5 once then press button 4 once within 3 seconds. b.
FUNCTION SELECTION a. b. c. d. e. f. The function selection is programmable. Please follow the procedure. In disarming status, turn ignition on (must 5 seconds longer after last ignition off). Within 8 seconds, press valet switch 3 times, then press once again and hold it for 3 seconds.
J1-8 Automatic door lock On Off J1-9 Automatic door unlock On Off J1-10 Alarm period J1-11 Smart immobilized J1-12 Siren alarm duration Emergency override J1-13 way 8 cycles On 30 seconds J1-14 Default setting On Lock with footbrake No limit Off 60 seconds 2 pin code way Simple way FEATURE MENU 2: Function selection J2-1 J2-2 Anti car jacking function Anti car jacking mode Variable 1 Variable 2 set-up set-up (2 chirps) (3 chirps) Pre set value (1 chirp) Off On Mode C Mode B Variable 3
ON J2-9 Horn timing Ignition control J2-10 dome light J2-11 Channel 2 output J2-12 Channel 3 output 10ms 50ms On Off Momentary output Momentary output J2-13 Channel 4 output Momentary output J2-14 Default setting On 20ms 30ms Latched output Latched output and reset with 30 seconds timed ignition ON Latched output Latched output and reset with 30 seconds timed ignition ON Latched output Latched output and reset with 30 seconds timed ignition ON FEATURE MENU 3: Function selection Pre s
J3-6 level check level check level Cranking time 1.0s 0.6s 0.8s 2.
J1-4. ARM/DISARM WITH CHIRP Pre-set: Arm/Disarm will have chirp indication. Variable 1: Arm/Disarm will not have chirp indication. J1-5. ARMING DELAY TIME Pre-set: delay 3s. Variable 1: delay 30s. J1-6. LAST DOOR ARMING Pre-set: Turn ignition ON to OFF and close the last door. After 30seconds, the system will arm itself without lock. Variable1: Delete this feature. Variable2: Turn ignition ON to OFF and close the last door. After 30seconds, the system will arm itself with lock. J1-7.
J1-9.AUTOMATIC DOOR UNLOCK Pre-set: When the ignition turns from ON to OFF, doors will unlock immediately. Variable1: When the ignition turns from ON to OFF, door will not unlock. J1-10.ALARM PERIOD Pre-set: the system can only be triggered at most 8 times. Variable1: the system’s triggered times is no limited. J1-11.SMART IMMOBILIZE Pre-set: this feature exists. Variable 1: Delete this feature J1-12.
J2-2. ANTI CAR-HIJACKING MODE SELECT Pre-set: entry anti car-hijacking way is mode C. Variable 1: entry anti car-hijacking way is mode B. Variable 2: entry anti car-hijacking way is mode A. J2-3.PROGRAMABLE L1 OUTPUT SELECT Pre-set: Trunk (channel 1) output. Variable1: Trunk (channel 1) output and disarming Variable2: output pulse after start. The wire will provide a 1 seconds -300mA pulsed ground output after the vehicle is started under control of the remote start unit.
Variable 3: output pulse after shutdown. The wire will provide a 1 seconds -300mA pulsed ground output after the remote start unit shuts down. This output will occur regardless of whether the circuit times out or is manually terminated. Typically this output will be used to re-lock/re-arm the vehicle if the doors unlock automatically when the ignition circuit transitions to off or the factory anti-theft system is disarmed. J2-6.
J2-10. IGNITION CONTROL DOME LIGHT Pre-set: the dome light will off when ignition turn from off to on position, the dome light will illume (max: 30s) when ignition turn from on to off position. Variable 1: the dome light will not illume when ignition turn from on to off position. J2-11. CHANNEL 2 OUTPUT MODE SELECT Pre-set: Momentary output: Anytime, within 3 seconds press button 4 once then press button 2 once, CH2 will output-300 mA.
J2-13.CHANNEL 4-OUTPUT MODE SELECT Pre-set: Momentary output: Anytime, within 3 seconds press button 4 once then press button 4, CH4 will output -300 Ma. Variable1: Latched output: this selection will output a –300mA signal from the channel 4 output as soon as the channel 4 button is pressed and will continue until the button is pressed again.
J3-3. ENGINE CHECK SELECTION WHEN REMOTE START Pre-set: Engine check ON: remote start successfully, to detect voltage rise or RPM signal. (if voltage rise or RPM signal is interrupted suddenly, the unit will start two times). Variable 1: Engine check OFF: remote start successfully, to detect voltage rise or RPM signal. (if voltage rise or RPM signal is interrupted suddenly, the unit will not start). J3-4. CHECK MODE WHEN START Pre-set: Voltage checking type. Variable 1: RPM checking type. J3-5.
J3-9.REMOTE START WARM-UP DURATION Pre-set: 10 minutes. Variable1: 5 minutes. Variable2: 20 minutes. Variable3: 30 minutes. J3-10.PARKING LING OUTPUT DURING RUNNING MODE Pre-set: keeping flash during running mode. Variable1: keeping steady on during running mode. J3-11. TURBO MODE Pre-set: Turbo mode selection off. Variable 1: Turbo mode selection on. J3-12. EXTERNAL MODULE TYPE Pre-set: I data link mode Variable 1: Fortin mode; Variable 2: GP300 J3-13.
ELECTRICAL DC Supply voltage DC Tolerance voltage Current (With RF) 12V 9V~16V <17mA Current (Without RF) <10mA RF PARAMETERS – T53/T89 Frequency Battery life TX range (with RX04) Static current 915mHz Half a year 1000Meter <10uA NOTE: This device complies with Part 15 of the FCC Rules.
SK600 RX04 T89 RECEIVER OR OPTIONAL PC SETUP CABLE OPTIONAL SHOCK SENSOR IDATA UPGRADE PORT T89 RECEIVER ANT GREEN/WHITE (-) UNLOCK OUTPUT -3 OPTIONAL 00mA BLUE/WHITE (-) LOCK OUTPUT -300m PC SETUP CABLE A VALET SWITCH LED FUSE BOX OPTIONAL TEMPERATURE SENSOR 30A FUSE RED +12V 30A FUSE 12V BATTERY RED +12V GREY/YELLOW DISARM IN + BORWN/YELLOW HOOD TRIGGER BROWN DOOR TRIGGER YELLOW IGNITION INPUT + GREY/WHITE ARM IN + BROWN/WHITE TRUNK TRIGGER - PURPLE (START) YELLOW IGN1 ORANGE ACC BROWN IG
STATEMENT changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.