Valet Switch LED:
Button switch + LED diagram is listed below, including 2 Buttons and 1 LED.
LED
Button 1
Button 2
HEU valet switch operation.
2 buttons are defined as Button 1 and 2, please refer to the above diagram
1.) Self-Geofence: Press Button 1 once to activate self-Geofence. LED will be continuous ON. Press the button
again to deactivate self-Geofence. LED will be OFF.
2.) Help button: Press Button 1 for 2 seconds: send HELP request message to the server. LED will flash 3 times.
3.) Panic Button: Press Button 2 once, the unit will send emergency report to the server. LED will flash 6 times.
Press Button 2 once, panic will be released.
4.) Emergency-Release Button: Press Button 1+2 together for 3 times when ACC on, the unit will emergency
Release. LED will flash 9 times.
5.) Intelligent power saving and control: Press button1+2 for 5 seconds., the unit will cut power of backup
battery.
V. PC SETUP AND SYSTEM INITIATION
PC setup Procedure:
1.) Connect the 3 pin serial cable to HEU PC setup port.
2.) Open the PC setup program.
3.) Select the correct COM port for communication.
4.) Power on the device or press the reset button for at least 1 second.
5.) Click “ok” to start the program
Note that, if the connection fails, please check the cable connection is secured correctly. Press the reset button
for a longer time, e.g. another 2 seconds.
A. LOGIN dialog window
Connect 3 pin DB9 serial cable to HEU PC setup port. Choose the correct COM port, and click “OK”.
Note that: it is necessary to power on and reset the PORTMAN device soon after starting the PC setup program.
PC setup program will detect the hardware for 60 seconds. If no hardware is detected, it will exit.
During the opening up screen shown as below, user can press “Esc” key to terminate the program.