(4) ‘Duty on’ or ‘Duty off’ reports / ‘Status on’ Status off’ reports
Press the button (the LED will be temporally stay off) and release it when the LED flashes 3 times. After
releasing it, a ‘Duty on’ report will be sent out. To deactivate: Press the button (the LED will be temporally
stay off) and release it when the LED flashes 3 times. After releasing it, a ‘Duty off’ report will be sent out.
(5) Emergency release to exit ‘ARM’, ‘Anti-carjacking’ or ‘Panic’ modes.
ACC ON, press the button (the LED will be temporally stay off) and release it when the LED flashes 5 times.
After releasing it, ‘ARM’, ‘parking light’, and ‘horn’ outputs will back to normal (Disarm) status.
(6) Enter code learn mode or exit.
ACC on and then press the button (the LED will be temporally stay off) and release it when the LED flashes
4 times. After releasing it, the horn will chirp three times to indicate system entered code learn mode; Turn
ACC off to exit code learn mode and there is no sound for indication.
(7) Enter valet mode or exit.
ACC on and then press the button (the LED will be temporally stay off) and release it when the LED flashes
8 times. After releasing it, the horn will chirp two times to indicate system entered or exit valet mode.
V. STATUS INDICATOR
System LED:
RED: Power indicator. When the unit power on, the led will light all the time. When power cut off the unit
works with internal battery, the led will flash until all the report is sent to server.
YELLOW: GSM/GPRS indicator. Yellow LED will flash when the device is connected to the server with
valid GPRS connection. It will stay continuously on when it is in GSM mode. It will stay off if there is no
GSM reception.
Green: GPS indicator. This LED will be ON when the unit received a valid GPS data.
Note that the Green LED indication will not be valid until the system goes to the working mode, normally
30 seconds after power on.
VI. BUILD IN ALARM OPERATION (Optional)
User can use the BUILD IN ALARM to perform all the car alarm function. For detail, refer to the BUILD
IN ALARM OPERATION manual.
VII. PC SETUP AND SYSTEM INITIATION
PC setup Procedure:
(1.) Connect the 4pin to RS232 cable to the DB9 port.
(2.) Open the PC setup program.
(3.) Select the correct COM port for communication.
(4.) Click “ok” to start the program
(5.) Power on the device or press the reset button until red LED turn off.
Note that, if the connection fails, please check the cable connection is secured correctly. Press the reset
button for a longer time, e.g. another 3 seconds.