User Manual
14
3. [Local report]:
Automatic report can be configured in this section. To activate the function(s), please select “√” in checkbox
and fill in data in the textbox.
The reports will be summarized as
(1) Intelligent report
Parameters: On/Off, Report time when moving, Report time when stop, and threshold speed. Report when
speed less than a preset value (refer the following 1.5 Km/Hr), and it will send stop report after a preset time
(refer the following 120Sec). (min. speed is 0.1 km/Hr, max. speed is 1000 km/Hr).
(2) Intelligent history report (record the report in the system’s flash ram)
Parameters: On/Off, Report time when moving, Report time when stop, and threshold speed. (min. speed is
0.1 km/Hr, max. speed is 1000 km/Hr).