User's Manual

2
Three LED indicate the status of the system:
Power indicator: When the unit power on, the led will flash 1time/3sec by green. If the power has low status,
the LED will change to red. when the battery charge ok then power LED will change to green. If tamper switch
is triggered, the power indicator will flash twice continuously; if door sensor is triggered, the power indicator
will flash 5 times continuously
GPS indicator: LED is GREEN when the unit has acquired a valid GPS signal, and it will flash when the unit is
searching GPS signal.
GSM/GPRS indicator: Orange LED will flash when the device is connected to the server with valid GPRS
connection. It will stay continuously on when it is in GSM mode. It will stay off if there is no GSM reception.
Note that the GSM/GPRS and GPS LED’s indication will not be valid until the system goes to the working
mode, normally 30 seconds after power on.
II. The main unit’s housing with Strong Magnetic Gives You Easy Instant Install Placement!
Just like we put you in control on how and when your CTS-100 reports to you with your own online controls,
we also put YOU in control of how you want your CTS-100 installed on any container or vehicle.
In addition, the unit has built-in door magnetic sensor, it used to detect the container door status.
III. BASIC FUNCTIONS
FUNCTIONS APPLICATIONS
GPS
GPS receiver will output a complete position, velocity, and time (PVT) solution in the
NMEA Version 3.0 protocol.
GPRS, SMS
GPRS use standard TCP or UDP communicate protocol. If the GPRS service is failed,
the SMS mode will be turned on for emergency use.
Button Power switch
PC-setup
Initialize the unit and program the device, including Network APN, server IP address,
user message, report control, and Geo-fence setting, etc …
Note that Network APN and server IP details must be set before the installation.
Standard Report
Automatic report for tracking purpose:
Fixed time report
Fixed distance report
Trigger report
History data store 900 report can be saved in unit and read from server and pc-setup