16
&&Y04,[connection time],[report interval]:
For example: &&Y04,3600,60
When received this command, system will connect to server in the next 3600 seconds, and send one report
out every 60 seconds.
Low battery report:
Low battery warning report (to alert user when the external battery level is low)
Parameters: On/Off, and warning battery level for report. For example, 30 to represent 30% lower level report.
The system will ignore the parameter with a value ‘0 to prevent continuous non-stop reporting. Low battery,
unit will cut power of GPS, only call function will be activated.
Acceleration sensor:
To determine whether CTS-100 is moving or not, user can select the sensitivity of the “acceleration sensor”. It
is distinguished by the tilt angle of the device. If the unit tilted more than the degree set here, CTS-100 will be
in moving mode. Otherwise, it will be in stop mode. The smaller the parameter of degree for the sensor set in
pc-setup is, the higher the sensitivity is. Otherwise, the result is the opposite.
You can select the Acceleration sensor trigger report to be sent or not, while the unit is moved. “Select” (by
click), the related reports will be sent. Otherwise the report will be ignored, when the device is moved.