Specification
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
ORDERING INFORMATION
LD4B EU4B 4LBSW 4LBDW
ENERGY DATA
Sound Rating: Class A standards
(Values at non-dimming line voltage)
Minimum Starting Temperature: -30°C (-22°F)
EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer)
Input Voltage: UNV (120V - 277V)
Power Factor: >0.90
(at nominal input 120-277 VAC & 100% of Rated Output Power)
Input Frequency: 50/60Hz
1000 Lumen D010 1500 Lumen D010
Input Power: 11W THD: <14% Input Power: 15.5W THD: <13%
120V Input Current: 0.09A 277V Input Current: 0.04A 120V Input Current: 0.13A 277V Input Current: 0.06A
2000 Lumen D010 3000 Lumen D010
Input Power: 21.2W THD: <9% Input Power: 27.6W THD: <10%
120V Input Current: 0.18A 277V Input Current: 0.08A 120V Input Current: 0.23A 277V Input Current: 0.10A
4000 Lumen D010
Input Power: 41.6W THD: <13%
120V Input Current: 0.35A 277V Input Current: 0.15A
120V 277V
Lumens Inrush (A) Duration (ms) Inrush (A) Duration (ms)
1000 Lumen D010 1.02 0.041 2.18 0.021
1500 Lumen D010 1.02 0.042 2.24 0.064
2000 Lumen D010 1.02 0.077 2.43 0.027
3000 Lumen D010 1.15 0.067 3.26 0.027
4000 Lumen D010 1.2 0.088 3.9 0.03
ENERGY
SAMPLE NUMBER: LD4B15D010IEMBOD
Housing Lumens
1
Voltage Driver Options
LD4B=LED Downlight 4”
Nominal Aperture
LD4BCP=LED Downlight 4”
Nominal Aperture,
Chicago Plenum
10=1000 lumens
15=1500 lumens
20=2000 lumens
30=3000 lumens
40=4000 lumens
50=5000 lumens
7
60=6000 lumens
7
Blank=120-277V
3=347V (step down
transformer)
1000-4000
D010=0-10V Dimming, 1% to 100%, 120V-277V
D010TR=0-10V or Line Voltage Dimming, 5% to
100%, 120V-277V
DE010=0-10V Dimming, 0% to 100%, 120V-277V
D5LT=Fifth Light® (DALI) Dimming, 0% to
100%, 120V-277V
DMX=DMX/RDM Dimming, 0% to 100%,
120V-277V
7
DL2=Lutron® Hi-Lume Forward Phase
Dimming, 1% to 100%, 120V Only
DL3=Lutron® Hi-Lume 3 Wire Dimming, 1% to
100%, 120V-277V
DLE=Lutron Ecosystem dimming 1% to 100%,
120V-277V
DLV=Low voltage dimming driver (1-100%) for
use with DLVP system (3000 lumen and
below)
3,6
5000-6000
D010TE=0-10V 1% or trailing edge 10%,
120-277V (120V only with trailing edge
dimming)
EMBOD=Bodine® Emergency Module with Remote Test
Switch
3
EM7=7W Emergency Module with Remote Test Switch
3, 4
EM14=14W Emergency Module with Remote Test Switch
3, 4
EMV7=7W Low Voltage Emergency Module with Remote Test
Switch
3,4
EMV14=14W Low Voltage Emergency Module with Remote
Test Switch
3,4
SWPD1=Factory installed WaveLinx tilemount daylight sensor
(includes control module, sensor, cable, and tile mount)
3, 6
LWTPD1=Factory installed LumaWatt Pro wireless sensor kit
3, 6
SAMPLE NUMBER: EU4B10208035
Power Module Lumen Levels
1
CRI Color
EU4B=4” Universal LED
Module
1020=1000, 1500, 2000 lumens
3040=3000-4000 lumens
5000=5000 lumens
7
6000=6000 lumens
7
1015IC=1000, 1500 lumen
IC rated
80=80 CRI Minimum
90=90 CRI Minimum
97=97 CRI Minimum
80 CRI
27=2700K
30=3000K
35=3500K
40=4000K
50=5000K
90 CRI
24=2400K
27=2700K
30=3000K
35=3500K
40=4000K
50=5000K
97 CRI
27=2700K
30=3000K
Dim 2 Warm
109030D2W=1000 lumen, 90 CRI, Dim 2 Warm, IC rated
159030D2W=1500 lumen, 90 CRI, Dim 2 Warm, IC rated
209030D2W=2000 lumen, 90 CRI, Dim 2 Warm
309030D2W=3000 lumen, 90 CRI, Dim 2 Warm
SAMPLE NUMBER: 4LBM1LIE
Trim Distribution Flange Finish
4LB=4” LED SW=Single Wall Wash
DW=Double Wall Wash
CW=Corner Wall Wash
LWW=Lensed Wall Wash
0=White Polymer Trim Ring
1=Self-flanged
6
2=White Painted Self-flanged
LI=Specular Clear
H=Semi-Specular Clear
WMH=Warm Haze
WH=Wheat
GPH=Graphite Haze
B=Specular Black
Accessories
TRM4=Metal Trim Ring, Specify Color
2
TRR4=Rimless Trim Ring
2
PRR4=Rimless Plaster Ring for Flush Mount
2
Bar Hangers
HB26=C-channel Bar Hanger, 26” Long, Pair
HB50=C-channel Bar Hanger, 50” Long, Pair
RMB22=Wood Joist Bar Hanger, 22” Long, Pair
Transformers
H347=347 to 120V Step DownTransformer, 75VA
H347200=347 to 120V Step Down Transformer, 200VA
Connected Solutions
PORLWTPD1=LumaWatt Pro wireless sensor kit (0-10V only) field installed
6
TMSWPD1 = WaveLinx tilemount daylight sensor (includes control module, sensor, cable and tile mount)
field installed
6
Notes:
1 Nominal Lumens will vary depending on selected color, driver
and reflector finish.
2 Order spun trim with polymer trim ring.
3 Not available with Chicago Plenum.
4 ULus approved only.
5 Flange is teh same finish as reflector.
6 Refer to system specifications for additional information,
features, and benefits. Order either factory installed option or
accessory. Use with 0-10V driver.
7 Product is marked spacing and must be installed with the
following minimum spacing
- Center to center of adjacent luminaires: 36”
- Center of luminaire to side of building member: 18”
- Minimum overhead: ½”