Installation Guide

ASSEMBLY INSTRUCTIONS
5
GND
3. Twist lock GU10 bulbs (F) into threaded socket (B).
(See Fig. 3.)
4. Wire connection guide (See Fig. 4.):
a.) Ground wire:
For installation in the United States:
Wrap ground wire from outlet box around
ground screw (FF) on mounting bracket (EE),
no less than 2 in. from wire end. Tighten
ground screw (FF). If fixture is supplied with
a ground wire, connect to outlet ground wire
with an extra wire connector (not included).
For installation in Canada:
If fixture is supplied with ground wire, wrap
ground wire around ground screw (FF) on
mounting bracket (EE). Tighten ground
screw (FF).
b.) Supply wire:
Make wire connections, with wire
connectors (AA), following the
reference chart listed below.
*NOTE:
When parallel wire (SPT I & SPT II) is used.
The neutral wire is square shaped and ridged
and the hot wire will be round in shape and
smooth. (See Fig. 5.)
Fig. 5
CONNECT, HOT, BLACK OR RED OUTLET SUPPLY WIRE TO: CONNECT, NEUTRAL, WHITE OUTLET SUPPLY WIRE TO:
Black White
* Parallel Cord (round & smooth) * Parallel Cord (square & ridged)
Clear, Brown, Gold or Black without Tracer (colored stripes) Clear, Brown, Gold or Black with Tracer (colored stripes)
Insulated Wire (not green) with copper metal conductor. Insulated Wire (not green) with Silver metal conductor.
Fig. 4
EE
Mounting
Bracket
Ground
Screw
FF
Hardware Used
Wire Connectors
AA
GND
EE
FF
Fig. 3
F
x 2
x 1
x 1