Installation Guide

8
Collection Bag (Figure 10)
WARNING: Turn off and unplug the tool before making any adjustments or
removing or installing accessories.
a. Attach bag (J) to either side of chip discharge
chute (F). Empty bag often to prevent clogging.
b. To prevent chips from coming out opposite side
of chip discharge chute, move chip deflector lever
(G) to the opposite side of the bag.
Vacuum Adaptor (Figure 11)
WARNING: Turn off and unplug the tool before making any adjustments or
removing or installing accessories.
a. Slide the vac adaptor (K) over the chip discharge
chute (F).
b. Connect a vacuum cleaner hose (not included) to
the adaptor.
c. To prevent chips from coming out opposite side
of chip discharge chute, move chip deflector lever
(G) to the opposite side of the adaptor.
To Change Blades (Figure 12)
WARNING: Turn off and unplug the tool before making any adjustments or
removing or installing accessories.
WARNING: Cut Hazard. Planer blades are sharp and must be handled with care.
NOTE: The PC60THP has two blades, one on each side of the blade drum. Any
operation or adjustment should be made to both blades. The cutting blades provided
with this tool are reversible. An extra set of blades is included.
To Remove Blade from Planer
a. Place planer upside down as shown in figure 12.
b. Loosen the three nuts (N) using the wrench (L)
supplied.
c. Rotate the blade guard (O) downward. Carefully
remove the blade (M) by sliding it out of the
holder. A piece of wood may be used for this
purpose.
d. Reverse the blade so that the unused side
comes in position. If both sides are worn, the
blade must be replaced.
To Reinstall Blade
a. Slide the blade sideways into the holder until it is against the end stop. Blade
groove must be toward back of unit.
b. Securely tighten the three nuts using the wrench supplied.
c. Rotate the blade drum 180 degrees and repeat for other blade.
d. Always replace both blades.
12
N
M
O
L
10
F
J
G
11
F
K
G