Instruction manual ESPAÑOL: PÁGINA 25 FRANÇAIS: PAGE 49 Direct Drive Oil Lube Portable Air Compressor Model CLFRP350 To learn more about Porter-Cable visit our website at: http://www.porter-cable.com ® IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No.
SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts within the motor and pressure switch to spark.
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use. If tank develops a leak, replace it immediately with a new tank or replace the entire compressor. Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Never operate the compressor outdoors when it is raining or in wet conditions. Never operate compressor with protective covers removed or damaged. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
HAZARD WARNING: Risk of Burns What Could Happen How To Prevent It Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool. Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
HAZARD WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Happen How To Prevent It Oil can leak or spill and could result in fire or breathing hazard; serious injury or death can result. oil leaks will damage carpet, paint or other surfaces in vehicles or trailers. Always place COMPRESSOR on a protective mat when transporting to protect against damage to vehicle from leaks.
GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
ASSEMBLY To Add Oil To Pump n/line art-misc/misc/dip stick Risk of Unsafe Operation. DO NOT ATTEMPT TO OPERATE THIS AIR COMPRESSOR WITHOUT FIRST ADDING OIL TO THE CRANKCASE. Serious damage can result from even limited operation unless filled with oil and broken in correctly. Make sure to closely follow initial start-up procedures. Risk of Unsafe Operation. COMPRESSORS ARE SHIPPED WITHOUT OIL. A small amount of oil may be present in the pump upon receipt of the air compressor.
INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Description of Operation Become familiar with these controls before operating the unit.
Dipstick: Indicates the amount of oil in the pump, the + mark indicates full and the - mark indicates oil needs to be added. See Oil paragraphs in the Maintenance section for instructions. Motor Thermal Overload Protector (not shown): The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.
3. Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.) 4. Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period. 5. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start. 6. Run the compressor for 20 minutes.
MAINTENANCE To ensure efficient operation and longer life of the air compressor unit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an unit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment.
5. Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, and then reinstalled.
4. 5. 6. Replace the oil drain plug (B). Slowly fill crankcase with oil. Crankcase capacity is 6 fluid ounces (177.4 ml). Oil level should be at the + (full) mark on the dipstick. Replace dipstick (A). Air Filter - Inspection and Replacement Risk of Burns. Compressor head and cylinder sleeve are very hot. Do not touch. Allow compressor to cool prior to servicing. A dirty air filter will not allow the compressor to operate at full capacity. Keep the air filter clean at all times. 1.
SERVICE AND ADJUSTMENTS ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN. Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. To Replace or Clean Check Valve 1. Release all air pressure from air tank.
STORAGE Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "OFF" and unplug unit. 3. Risk of Flying Objects. Pull the regulator knob out and turn counter-clockwise to set the outlet pressure to zero when removing hose or accessories to prevent hose backlash. 4. Remove the air tool or accessory. 5.
TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. PROBLEM Excessive tank pressure - safety valve pops off. CAUSE Pressure switch does not shut off motor when compressor reaches "cutout" pressure. Pressure switch "cut-out" too high.
PROBLEM CAUSE Pressure reading It is normal for "some" on the regulated pressure drop to occur. pressure gauge (if equipped) drops when an accessory is used. CORRECTION If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator as instructed in the Operation section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced.
PROBLEM Motor will not run. CAUSE Motor overload protection switch has tripped Tank pressure exceeds pressure switch "cut-in" pressure. Check valve stuck open. Loose electrical connections. CORRECTION Let motor cool off and overload switch will automatically reset. Motor will start automatically when tank pressure drops below "cut-in" pressure of pressure switch. Remove and clean, or replace. Refer to the "To Replace or Clean Check Valve" in the "Service and Adjustment" section.
PROBLEM CAUSE CORRECTION Knocking Noise. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Defective check valve. Remove and clean, or replace. Refer to the "To Replace or Clean Check Valve" in the "Service and Adjustment" section. Compressor mounting screws loose. Tighten mounting screws,see Parts manual for torque specifications. Carbon build-up in pump. Have checked by a Trained Service Technician. Squealing sound.
LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS - Limited warranty on oil-lubricated air compressor pumps.