ESPAÑOL: PÁGINA 17 FRANÇAISE : PAGE 33 Instruction manual Side Stack Compressor MODEL C3001 To learn more about Porter-Cable visit our website at: http://www.porter-cable.com IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference.
SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts within the motor and pressure switch to spark.
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use. If tank develops a leak, replace it immediately with a new tank or replace the entire compressor. Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Never operate the compressor outdoors when it is raining or in wet conditions. Never operate compressor with protective covers removed or damaged. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
HAZARD WARNING: Risk of Burns What Could Happen How To Prevent It Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool. Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
HAZARD WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Happen How To Prevent It Oil can leak or spill and could result in fire or breathing hazard; serious injury or death can result. oil leaks will damage carpet, paint or other surfaces in vehicles or trailers. Always place COMPRESSOR on a protective mat when transporting to protect against damage to vehicle from leaks.
SPECIFICATIONS Model No. Horsepower Peak Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity (Gallon) Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 PSIG SCFM @ 90 PSIG C3001 3.0 1.875" 1.250" 120 15 amps Time Delay 4 120 PSIG 150 PSIG 4.9 3.5 GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
ASSEMBLY Unpacking 1. Remove unit from carton and discard all packaging. INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor G G G Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling.
Extension Cords Voltage and Circuit Protection Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. If an extension cord must be used, be sure it is: Refer to the specification chart for the voltage and minimum branch circuit requirements.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Tank Pressure Gauge On/Auto/Off Switch Universal QuickConnect Body Outlet Pressure Gauge Regulator Pressure Switch Safety Valve Description of Operation Become familiar with these controls before operating the unit.
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled. Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Before Each Start-Up: How to Start: 1. Place On/Auto/Off lever to "OFF". 1. 2. Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 3. Attach hose and accessories. 2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place.
To Drain Tank 1. Set the On/Auto/Off lever to "OFF". 2. Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 5. Drain water from air tank by opening drain valve on bottom of tank. Water will condense in the air tank.
STORAGE Before you store the air compressor, make sure you do the following: 1. 2. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 7. Set the On/Auto/Off lever to "OFF" and unplug unit. After the water has been drained, close the drain or drain valve.
LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS - Limited warranty on oil-lubricated air compressor pumps.
ENGLISH: PAGE 1 ESPAÑOL: PÁGINA 17 Manuel d’instructions Compresseur à pile latérale MODÈLE C3001 Pour de plus amples renseignements concernant Porter-Cable, consultez notre Website à l’adresse suivante : http://www.porter-cable.com IMPORTANT Veuillez vous assurer que la personne qui utilise cet outil lit attentivement et comprend ces instructions avant de commencer à utiliser l’outil. La plaque des numéros de modèle et de série est située sur le boîtier principal de l’outil.
MESURES DE SÉCURITÉ - DÉFINITIONS Ce guide contient des renseignements importants que vous deviez bien saisir. Cette information porte sur VOTRE SÉCURITÉ et sur LA PRÉVENTION DE PROBLÈMES D'ÉQUIPEMENT. Afin de vous aider à identifier cette information, nous avons utilisé les symboles ci-dessous. Veuillez lire attentivement ce guide en portant une attention particulière à ces symboles. Indique un danger imminent qui, s'il n'est pas évité, causera de graves blessures ou la mort.
CONSIGNES DE SÉCURITÉ IMPORTANTES Conserver ces directives Un emploi ou un entretien non appropriés de ce produit peut causer des blessures graves et des dommages à la propriété. Lire attentivement tous les avertissements et les directives d'utilisation avant d'utiliser cet appareil. DANGER AVERTISSEMENT : Risque d'explosion ou d'incendie Risque Prévention Les étincelles qui proviennent des contacts électriques du moteur et du manostat sont considérées normales.
DANGER AVERTISSEMENT : Risque d'éclatement Réservoir d'air : Les conditions suivantes peuvent affaiblir les parois du réservoir et provoquer une explosion violente du réservoir qui risque de causer des dommages à la propriété ou des blessures graves. Risque Prévention Le défaut de vidanger de façon appropriée l'eau condensée dans le réservoir risque de causer la rouille et l'amincissement des parois en acier du réservoir. Purger le réservoir quotidiennement ou après chaque utilisation.
DANGER AVERTISSEMENT : Risque de choc électrique Risque Prévention Votre compresseur d'air est alimenté par électricité. Comme avec tous les appareils électriques, si l'appareil n'est pas utilisé de façon appropriée, il peut causer des chocs électriques. Ne jamais faire fonctionner le compresseur à l'extérieur lorsqu'il pleut ou dans des conditions humides. Ne jamais faire fonctionner le compresseur sans les couvercles de protection ou lorsque ceux-ci sont endommagés.
DANGER AVERTISSEMENT : Risque de brûlures Risque Prévention Le fait de toucher aux surfaces de métal exposées telles que la tête du compresseur ou les tubes de sortie peut causer de graves brûlures à la peau. Ne jamais toucher aux pièces de métal exposées du compresseur durant ou immédiatement après le fonctionnement. Le compresseur demeure chaud pendant plusieurs minutes après le fonctionnement.
DANGER AVERTISSEMENT : Risque de dommages à la propriété pendant le transport du compresseur (incendie, inhalation, dommages aux surfaces du véhicule) Risque Prévention Des fuites ou des déversements d'huile peuvent se produire et entraîner des risques d'incendie, ou des problèmes aux voies respiratoires, des blessures graves ou la mort. Des fuites d'huile endommagent les tapis, la peinture et toute autre surface des véhicules ou des remorques.
SPECIFICATIONS Modèle no Puissance de crête Alésage Course Tension monophasée Exigence minimale du circuit de dérivation Genre de fusibles Capacité du réservoir d'air (gallons) Pression l'amorçage approx. Pression de rupture approx. pi³/min standard (SCFM) à 40 lb/po2 pi³/min standard (SCFM) à 90 lb/po2 C3001 3,0 1,875 po (4,8 cm) 1,250 po (3,2 cm) 120 15 a À retardement 4 (15,1) 120 150 4,9 3,5 LEXIQUE Veuillez vous familiariser avec ces termes avant d'utiliser l'appareil.
ASSEMBLAGE Déballage 1. Retirez l'appareil de sa boîte et jetez tout l'emballage. INSTALLATION MONTAGE DE L'APPAREIL 2. Emplacement du compresseur d'air G Le compresseur d'air doit être situé dans un endroit propre, sec et bien aéré. G Le compresseur d'air devrait être situé à une distance d'au moins 12 po (30 cm) de tout mur ou autre obstruction qui pourrait bloquer le débit d'air. G La pompe et la tôle de protection du compresseur sont conçus pour permettre un refroidissement approprié.
Rallonges Protection contre la surtension et protection du circuit L'utilisation d'une rallonge électrique est déconseillée. L'utilisation d'une rallonge produira une chute de tension qui entraînera une perte de puissance au moteur ainsi qu'une surchauffe. Au lieu d'utiliser une rallonge électrique, augmentez plutôt la longueur du boyau d'air en connectant un autre boyau à l'extrémité. Connectez des boyaux supplémentaires au besoin.
UTILISATION Familiarisez-vous avec votre compresseur d'air LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce guide pour références ultérieures.
Système de refroidissement (non illustré) : Le compresseur d'air est doté d'un système de refroidissement d'avant garde. Le cœur de ce système est un ventilateur à technologie avancée. Il est tout à fait normal que ce ventilateur souffle de l'air au-dessus de la tête de la pompe, le manchon du cylindre et le carter. Vous savez que le système de refroidissement fonctionne bien lorsque de l'air est expulsé.
Avant chaque mise en marche : Mise en marche : 1. Placez le levier «On/Auto/Off» à la position «OFF». 1. 2. Tirez le bouton du régulateur et tournez-le dans le sens contraire des aiguilles d'une montre jusqu'à ce qu'il s'arrête. Poussez le bouton pour le verrouiller. Raccordez le boyau et les accessoires. 3. REMARQUE : Le boyau ou l'accessoire doit être muni d'une fiche à connexion rapide si la sortie d'air est équipée d'une douille à connexion rapide. Risque d'éclatement.
Vidange du réservoir 1. 2. 3. 4. 5. Réglez le levier marche/automatique/arrêt «On/Auto/Off» à la position d'arrêt «OFF». Tirez le bouton du régulateur et tournezle dans le sens contraire des aiguilles d'une montre jusqu'à ce qu'il s'arrête. Poussez le bouton pour le verrouiller. Enlevez l'outil pneumatique ou l'accessoire. Tirez l'anneau de la soupape de sûreté pour permettre à l'air de purger du réservoir jusqu'à ce que la pression dans le réservoir se situe à environ 20 lb/po2.
RANGEMENT Risque d'éclatement. L'eau dans le réservoir d'air peut condenser. Si le réservoir n'est pas vidangé, l'eau corrodera et affaiblira les parois du réservoir d'air, causant ainsi un risque d'éclatement du réservoir. Avant de ranger le compresseur d'air, effectuez les étapes suivantes : 1. Revoyez la section intitulée « Entretien » des pages précédentes et exécutez l'entretien requis. 2. Placez le levier « ON/AUTO/OFF » à la position d'arrêt « OFF » et débranchez l'unité. 3.
GARANTIE LIMITÉE PORTER-CABLE CORPORATION garantit à l'acheteur original que tous les produits couverts par cette garantie sont exempts de défauts de matériaux et de fabrication.