Instruction manual ESPAÑOL: PÁGINA 21 FRANÇAIS: PAGE 41 Generator MODEL BSI525 Shown with optional portability kit To learn more about Porter-Cable visit our website at: http://www.porter-cable.com IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. Type Serial No.
SPECIFICATIONS MODEL HORSE POWER RATED/SURGE WATTS VOLTAGE AMPERAGE PHASE FREQUENCY ENGINE SPEED MAX. AMBIENT TEMP. FUEL CAPACITY RUN TIME @ 50%/100% BSI525 10.0 5250/6500 120/240 43.7/21.8A SINGLE 60 Hz 3600 RPM 104° F 7 GALLONS 13.2/8.1 HRS CONSUMER SAFETY INFORMATION Read Operators Manual. Do not operate equipment until you have read operators Manual for Safety, Assembly, Operation, and Maintenance Instructions. This product may not be equipped with a spark arresting muffler.
SAFETY GUIDELINES / DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections. indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
RISK OF ELECTROCUTION AND FIRE (Continued) HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT Operation of generator in rain, wet, icy, or flooded conditions. Water is an excellent conductor of electricity! Water which comes in contact with electrically charged components can transmit electricity to the frame and other surfaces, resulting in electrical shock to anyone contacting them. Operate generator in a clean, dry, well ventilated area. Make sure hands are dry before touching unit.
RISK OF FIRE HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT Attempting to fill the fuel tank while the engine is running. Gasoline and gasoline vapors can become ignited by coming in contact with hot components such as the muffler, engine exhaust gases, or from an electrical spark. Turn engine off and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires.
RISK OF INJURY AND PROPERTY DAMAGE WHEN TRANSPORTING GENERATOR HAZARD Fire, Inhalation, Damage to Vehicle Surfaces WHAT CAN HAPPEN Fuel or oil can leak or spill and could result in fire or breathing hazard, serious injury or death can result. Fuel or oil leaks will damage carpet, paint or other surfaces in vehicles or trailers. HOW TO PREVENT IT If generator is equipped with a fuel shut-off valve, turn the valve to the off position before transporting to avoid fuel leaks.
RISK OF UNSAFE OPERATION (Continued) HAZARD Operation of voltage sensitive appliances without a voltage surge protector WHAT CAN HAPPEN HOW TO PREVENT IT Any gasoline operated household generator will incur voltage variations causing damage to voltage sensitive appliances or could result in fire. Always use a U.L. listed voltage sensitive surge protector to connect voltage sensitive appliances (TV, computer, stereo, etc.). Failure to use a U.L.
RISK OF MOVING PARTS HAZARD Contact with moving parts can result in serious injury. WHAT CAN HAPPEN The generator contains parts which rotate at high speed during operation. These parts are covered by guarding to prevent injury. HOW TO PREVENT IT Never operate generator with guarding or cover plates removed. Avoid wearing loose fitting clothing or jewelry which could be caught by moving parts. RISK FROM LIFTING HAZARD Lifting a very heavy object.
GROUNDING THE GENERATOR A grounding lug is supplied with the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information. NOTE: Your engine is already grounded to the frame by a grounding strap.
OPERATION KNOW YOUR GENERATOR Read this General Manual and Safety Rules before operation of your Generator. Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and adjustments. Save all manuals for future references. GENERATOR CAPACITY IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage to your generator and connected electrical devices.
Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire. Never attempt to “speed-up” the engine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user. You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances.
STOPPING ENGINE 1. 2. Disconnect all electrical loads. Turn ON/OFF switch to "OFF" position. 3. Close fuel shut-off valve. CONNECTING ELECTRICAL LOADS 1. Let engine run and warm up for five minutes after starting with no electrical load. Connect loads in the following manner to prevent damage to equipment: 2. Connect inductive load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools.
MAINTENANCE CUSTOMER RESPONSIBILITIES TABLE MAINTENANCE TASK Check oil level Before each use Every 25 Hours of Every Season X See Note 2 Clean Air Filter Assembly Prepare Unit for Storage Every 100 Hours of Every Season See Note 1 Change oil Check Spark Plug Every 50 Hours of Every Season X X X Prepare unit for storage if it is to remain idle for more than 30 days.
STORAGE If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage. Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliances. ENGINE PREPARATION 1. Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage. 2.
WATTAGE CALCULATIONS IMPORTANT Never exceed the rated capacity of your generator. Serious damage to the generator or appliance could result from an overload. 1. Starting and running wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool. 2. There are two types of electrical appliances that can be powered by your generator: A. Items such as radios, light bulbs, television sets, and microwaves have a "resistive load".
Example 3: 1500 Starting Watts 1150 Running Watts TOTAL =2650 Total Watts Generator must have a maximum capacity of at least 2650 watts. STARTING WATTAGE REQUIREMENTS 1. 2. 3. Some appliances and tools will list on the motor nameplate the starting and running voltage and amperage requirements.
HOUSEHOLD WATTAGE CALCULATOR DEVICES WITH HIGH STARTING (INDUCTIVE)LOADS RUN WATTS TIMES (X) START FACTOR APPLIANCE OR LOAD DEVICE* TYPICAL DEVICE WATTAGE** TOTAL 800 x 3 REFRIGERATOR/ FREEZER = 2400 = 600 x 3 SMALL REFRIGERATOR = 1800 = 2400 x 3 AIR COND.
TROUBLESHOOTING GUIDE PROBLEM CORRECTION CAUSE Engine will not 1. start 2. 1. 2. Add fuel or oil. Turn to "ON" position 3. 4. 5. Replace spark plug. Adjust choke accordingly. Open fuel shut-off valve. 7. Low on fuel or oil. Ignition switch in "Off" position. Faulty spark plug. Choke in wrong position. Fuel shut-off valve in closed position Unit loaded during startup. Spark plug wire loose. 1. Faulty receptacle. 2. 3. Circuit breaker kicked out. Defective capacitor. 4. Faulty power cord. 5.
LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS - Limited warranty on oil-lubricated air compressor pumps.
QUICK FACTS CALL 1-888-559-8550 TO FIND A LOCAL AUTHORIZED SERVICE CENTER NEAR YOU FOR REPAIRS AND SERVICE PART PURCHACES. ENGINE GAS Use clean, fresh gasoline with a minimum 87 octane rating. Do not add gasoline during or immediately after use. Refer to engine owner's manual for oil recommendations. ENGINE OIL Most generators are equipped with a low-oil shutdown. If the oil is low or if the Generator is not level, the engine will not start. WATTAGE WIRING BATTERY VOLT REG.