Owner's Manual
QUICK SETUP
Remove box and pallet Position evaporative cooler on level surface Wire into an appropriate outlet
Fill reservoir or attach water hose
2 4
5
1 3
This product needs to
be hardwired into an
appropriate electrical
outlet by a certied
electrician.
Fill the tank, then turn on the pump switch and the fan
For setup, Kuul
Comfort
TM
with FirePro Technology™
evaporative media should appear wet before starting
the fan. Check the water gauge to monitor water level
in tank. The water adjustment valve on each portable
evaporative cooler is set at max ow. However, ensure
the knob is turned completely to the right before use.
Turn to the left to increase water ow. If entrainment
occurs - water is spitting from the front of the product
- use the valve to decrease the water ow until
entrainment ceases.
Ensure proper airflow is available
Your Portacool portable evaporative cooler is meant
to be used in an open-air environment, such as a
warehouse or large shop. If you plan to use your
evaporative cooler in a more closed environment – such
as a garage or small shop – you must provide adequate
ambient airow to ensure your evaporative cooler
works at its highest efciency. When using in a semi-
closed environment, be sure to leave a door or window
open to allow for the proper amount of airow.
6