PORTACOOL CYCLONE OWNER’S MANUAL PAC2KCYC01, PACCYC02, PACCYC03, PACCYC04, PACCYC06
QUICK SETUP 1 2 Remove box and pallet 5 Position on level surface 3 Fill tank or attach water hose For setup, the KUUL® evaporative media should appear wet before starting the fan. The water adjustment valve on each Portacool portable evaporative cooler is set at max flow. However, ensure the knob is turned completely to the right before use. Turn to the left to increase water flow. Less water is required for cooling in more humid environments.
SAFETY OPERATION WARNINGS 1) Not for use by children 2) Not for use by persons with reduced physical, sensory or mental capabilities 3) Not for use by persons who have not reviewed the owner’s manual and familiarized themselves with the operation of the product. SAFE OPERATION To reduce the risk of electric shock, fire, or injury: • Do not operate any evaporative cooler with a damaged cord or plug. • Do not run power cord under carpeting or cover with throwrugs, runners or similar coverings.
OVERVIEW CYCLONE 3000 CYCLONE 2000 CYCLONE 1000 Adjustable louvers Adjustable louvers Adjustable louvers KUUL evaporative media KUUL evaporative media Power cord Water level sight window Water level sight tube Water level sight tube Drain located in back Control panel Water adjustment valve Hose connection KUUL evaporative media Drain located underneath Drain located in back Control panel Water adjustment valve Water adjustment valve Control panel Hose connection Hose connection Power c
OVERVIEW CYCLONE 2200 CYCLONE 3200 Adjustable louvers Adjustable louvers KUUL evaporative media KUUL evaporative media Water level sight tube Water level sight tube Drain located in back Control panel Power cord Water adjustment valve Hose connection Casters Drain located underneath Control panel Power cord Water adjustment valve Hose connection Casters
START UP PLACEMENT 1) Make sure there is a clear, unobstructed path in front of the evaporative cooler to provide maximum airflow. 2) If the evaporative cooler is positioned on a raised platform, ensure the platform is stable, well constructed and will not allow the evaporative cooler to tip over. Ensure it allows for the full weight of the evaporative cooler, including a tank full of water.
MAINTENANCE While the rugged, corrosion-resistant construction ensures low maintenance will be required, keeping your evaporative cooler clean will ensure it stays in peak operating condition. DAILY MAINTENANCE The pump should be turned off approximately 15 minutes before the fan is turned off, which allows the KUUL® evaporative media to dry out.
TROUBLESHOOT Turn off all power to your evaporative cooler before attempting to troubleshoot any of the following symptoms. For problems not listed, please contact customer service. SYMPTOM Evaporative cooler fails to start or deliver air REMEDY POSSIBLE CAUSES 1. No electricity to the evaporative cooler A. Circuit breaker tripped B. GFCI tripped C. Power unplugged or damaged 1. Check power A. Reset breaker* B. Reset GFCI* C. Plug in cord(s) or replace if damaged 2. Motor overheated and/or frozen 2.
TROUBLESHOOT SYMPTOM POSSIBLE CAUSES REMEDY Musty or unpleasant odor 1. Stale or stagnant water in tank 1. Drain, flush and clean tank 2. KUUL evaporative media is mildewed or clogged 2. Replace KUUL evaporative media 1. Too much water delivered to KUUL evaporative media 1. Make sure KUUL evaporative media is properly positioned in the frames and evaporative cooler is level 2. Leaking hose 2. Tighten connection or replace hose 1. Switch boot is too tight 1.
WARRANTY TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Portacool, LLC Technical Support Hot Line at 888-266-5243 for the distributor nearest you. You may also contact the Support Hot Line for consultation on troubleshooting and parts replacement. Please have serial number and model number of cooler available.
FAQ Q. What assembly is required? A. None. Your Portacool portable evaporative cooler is ready to use right out of the box. Q. How do I prepare my Portacool portable evaporative cooler for storage? A. Drain the evaporative cooler, wipe out the tank to ensure it is dry and clean, dry out the KUUL® evaporative media, cover the evaporative cooler and store in a dry place. Q. I ran my evaporative cooler for the first time and there is an unpleasant odor! A.
FAQ Q. What amount of moisture is added to the air by my evaporative cooler? A. An increase in humidity of approximately two to five percent is produced, depending on the temperature and humidity of the environment. This increase is not noticeable in a ventilated area where the air produced by the cooler is exhausted. Q. How long will the water supply last in my evaporative cooler’s tank? A.
FAQ HOW TO REPLACE YOUR KUUL EVAPORATIVE MEDIA Step 1 Be sure to unplug your Portacool portable evaporative cooler before doing any maintenance. Lock the casters to keep your evaporative cooler from moving while you are working. Remove the flap and KUUL® evaporative media from the evaporative cooler. The flap is attached at the top of the evaporative cooler with three screws. Remove the three screws and set the flap aside.
KEY PARTS 1000 2000 2200 3000 3200 MOTOR-017-01 MOTOR-016-01 MOTOR-016-01 MOTOR-013-07B MOTOR-013-07B PUMP PUMP-CYC-3 PUMP-CYC-3 PUMP-CYC-3 PUMP-CYC-3 PUMP-CYC-3 MEDIA PADMF4022/G PAD6019/22 PAD6019/22 PAD6022.5/26 PAD6022.
REGISTER Please complete this form and mail in a stamped envelope to: Portacool, 711 FM 2468, Center, TX 75935 or register online at: www.portacool.
NOTES
NOTES
NOTES
CUSTOMER SERVICE CONTACT 1-936-598-5651 • 1-800-695-2942 ORDERS@PORTACOOL.COM TECHNICAL/PARTS CONTACT 1-936-598-5651 • 1-800-695-2942 SUPPORT@PORTACOOL.COM VISIT PORTACOOL.COM Portacool, LLC • Manufacturer of Portacool™ portable evaporative coolers and KUUL® evaporative media 711 FM 2468 • Center, Texas 75935 • 936-598-5651 www.portacool.com • www.theKUULeffect.com P R O D U C T AT El manual está disponible en otros idiomas. Para descargar una copia digital, por favor visite www.portacool.com.