User Manual

The user interface includes touch sensitive buttons for operation of the
Hurricane 3600. The user interface also includes status indicator LEDs
and a 7-segment LED display to show the cooling unit’s status.
Power
The green Power LED is illuminated when the
unit is plugged in.
Water level
The red water level LED is illuminated when
the oat switch detects a low water level and the pump is not
being allowed to turn on. This LED
ashes if the pump is running during a
low water occurrence to indicate that
more water needs to be added in order
to continue running the pump.
Timer
The controller features ve pre-programmed modes which
control the fan / pump sequence for a pre-dened period. Each
touch of the program button cycles through the ve modes:
1HR, 2HR, 4HR, 8HR, and TIMER OFF. During the program run,
the user can adjust the maximum fan speed with the up and down
buttons. When the program is active, the Timer
LED will be on and, for ve seconds, the user
will be shown which program (1H, 2H, 4H, or
8H) is active.
Slider
The touch slider controls the speed setting of the fan. If the slid-
er is touched on the “+” end of the slider spectrum, then the fan
speed requested is the maximum, 100% (“HI”). If the slider is touched
on the “–” end of the slider spectrum, then the fan speed requested
is the minimum, 33% (“LO”). A
touch anywhere between the “+”
and “–” of the slider adjusts the
fan speed in 1% increments.
Pump
Press the pump button once to
power on and again to power
off. The green Pump LED is
illuminated when the pump is enabled. The
LED ashes slowly if continuously held and
the timer is disabled.
Fan
When the fan is off, touch the
Fan button once to turn the fan
on in full speed. When the fan is
on, touch of the Fan button again to turn the
fan off. The green Fan LED is illuminated when
the Fan is active. The LED ashes slowly if
continuously held and the timer is disabled.
7-Segment LED Display
LEDs are used to display the status of the cooling unit.
The green Timer LED is illuminated when the Timer button
is activated in 1, 2, 4, or 8-hour modes. The LED ashes
slowly if continuously held and ashes quickly if the timer is enabled
and then the Pump or Fan buttons are continuously held, prompting
the user to turn off the timer in order to exit fan and pump operation.
Two digits display the unit’s temperature, fan speed, and timer
program. If the unit does not have a temperature sensor connected,
the display will constantly show fan speed. If the unit does feature a
temperature sensor, then the temperature is displayed unless: a fan
speed change is being called upon either by means of a slider touch
or by the timer’s program. When a fan speed change is requested, the
fan speed will be displayed for 5 seconds before returning to the unit
temperature.
1
2
3
4
5
6
7
2
1
3
4
5
6
7
LED Speed Display.
“HI” or “LO” or %
CFM will be
illuminated.
LED Timer Display.
Shows one of the 5
modes: 1HR, 2HR,
4HR, 8HR, or OFF.
LED Temp Display.
Temperature of the
internal cooled air in
Fahrenheit or Celcius.
HURRICANE® 3600 USER INTERFACE
PRE-PROGRAMMED TIMER FUNCTION
1) PUMP STARTS (INCLUDES FIVE SECOND DELAY TO
ALLOW WATER TO START REACHING THE PADS)
2) FAN STARTS AT 100% (HI) SPEED (A “KICK START” FOR
BEST VARIABLE SPEED MOTOR OPERATION)
3) FAN RAMPS DOWN TO 50% SPEED
4) FAN RAMPS UP TO FULL SPEED IN 10% STEPS AT 1
MINUTE INTERVALS (BEGIN INCREASING AIRFLOW AS
THE PADS WET OUT FOR BEST EFFICENCY)
5) FAN RUNS AT MAXIMUM SPEED FOR THE DURATION OF
THE TIMER SETTING (100% SPEED IS DEFAULT, OR IT
CAN BE WHATEVER THE USER SELECTS)
6) PUMP SHUTS OFF WHEN TIMER SETTING EXPIRES
7) FAN RAMPS DOWN TO 50% SPEED
8) FAN RUNS 30 MINUTES (PAD DRYING PERIOD)
9) FAN SHUTS OFF