PORTACOOL OWNER’S MANUAL FOR PAC2K482S, PAC2K363S, PAC2K361S, PAC2K36HPVS, PAC2K24HPVS and PAC163SVT
TABLE OF CONTENTS READ AND SAVE THESE INSTRUCTIONS CONTENTS: QUICK SETUP GUIDE......................................................................... page 2 TROUBLESHOOTING ................................................................ pages 12-13 PRODUCT OVERVIEW .................................................................. pages 3-7 TECHNICAL SUPPORT AND WARRANTY ............................... pages 14-15 SAFETY INFORMATION ....................................................................
QUICK SET UP 1 2 Remove box and palette 5 Position product on level surface 3 Fill sump or attach water hose For setup, pads should appear wet before starting the fan. Check the water gauge to monitor water level in tank.The water Áow valve on each unit is set at max Áow. However, ensure the knob is turned completely to the left before use. Turn to the left to increase water Áow. Less water is reTuired for cooling in more humid environments. Fill the tank, then turn on the pump switch and the fan.
16" VERTICAL TANK OVERVIEW PAC163SVT This unit does NOT have a hose fill option.
24" HP OVERVIEW Control Panel Water Adjustment Valve Hose Connection Pad Flap Locking Casters Electrical Plug 4
36" OVERVIEW PAC2K36HPVS Control Panel Water Adjustment Valve Cord Wrap Hose Connection 5 Locking Casters Electrical Plug
48" OVERVIEW PAC2K482S Control Panel Water Adjustment Valve Hose Connection Cord Wrap Electrical Plug Locking Casters 6
SAFETY INFORMATION OPERATION WARNINGS 1) Not intended for use by children 2) Not intended for use by persons with reduced physical, sensory, or mental capabilities 3) Not intended for use by persons with lack of experience and knowledge, unless they have been given instruction and are supervised during operation 4) Children should be supervised to ensure they do not play with the evaporative cooler SAFE OPERATION 7R UHGXFH WKH ULVN RI HOHFWULF VKRFN ÀUH RU LQMXU\ • • • • • • • • • • • Do not operate an
GENERAL OPERATION (OHFWULFDO &RQQHFWLRQ PRODUCT MUST BE IN UPRIGHT POSITION WITH COOLING PADS INSTALLED! All models utilize a single power cord and control switches. Before connecting the plug to an outlet, ensure there is no standing water where the cord may lie or where the operator is standing. The use of separate multiple outlet devices is not recommended. When making electrical connections, ensure compliance to local and national codes. Use only with GFCI Protected Receptacles.
3) If placed near a wall or other obstruction, position the product a minimum of 3 feet (0.9 meters) from the wall or obstruction with pads facing the wall. This allows the unrestricted flow of warm air to the cooling pad side of the product. When using multiple products in close proximity, be sure to aim the product so the air flows complement each other to achieve maximum cooling capacity.
MAINTENANCE & STORAGE MAINTENANCE 1) Keep the product clean to ensure peak operating performance. 2) The rugged, corrosion-resistant construction ensures low maintenance will be reTuired. However, in dusty or dirty environments, optional filters are available from your distributor or at www.portacoolparts.com. DDLO\ MDLQWHQDQFH The pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the cooling pads to dry out and extend their life.
TROUBLESHOOTING The Portacool evaporative cooler consists of three systems — the fan system, the electrical system, and the water system. It is important to determine with which of the systems the problem is associated. Certain problems may be associated with more than one system. A careful check of all systems should be made to fully understand the extent of the problem.
The following troubleshooting guide is intended to address the most common symptoms which may occur. If you are unable to resolve the issue, please call Technical Support. Turn off all power to the evaporative cooler before attempting to troubleshoot any of the following symptoms. SYMPTOM POSSIBLE CAUSES REMEDY Product fails to start or deliver air 1. No electrical power to product A. Circuit breaker tripped B. GFCI tripped C. Cord(s) unplugged or damaged 2. Motor overheated and/or frozen 1.
TECHNICAL SUPPORT TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Portacool, LLC Technical Support Hot Line at 888-266-5243 for the distributor nearest you. You may also contact the Support Hot Line for consultation on troubleshooting and parts replacement. Please have serial number and model number of product available.
RETURNS RHWXUQHG MHUFKDQGLVH AXWKRUL]DWLRQ RMA PURFHGXUHV All Portacool evaporative coolers, parts, or materials being returned to Portacool, LLC for warranty replacement or repair reTuire an RMA (Return Merchandise Authorization) number. Warranty parts can be replaced by: 1. The distributor can purchase the part with an RMA number and will only be charged for the cost of the part, not for the shipping.
" VERTICAL TANK PARTS 3$& .
16" VERTICAL TANK PARTS 3$& 697 5(9,6(' POWERCORD-03F 2 BONNET-03 SPRAY BAR BONNET FOR 16” PAC 17 PAD6024/G 16” PAC REPLACEMENT PAD 3 BOX-UL-01 3SPD ELECTRICAL BOX 18 POLY-FTG-06 90DEG FITTING FOR SIGHT TUBE 4 CASTERS-HD-4 4” JS/VT HEAVY DUTY NON-LOCKING CASTER 19 PUMP-0140-1 PUMP ASSEMBLY FOR 16” UNIT 5 CASTERS-HD-4L 4” JS/VT HEAVY DUTY LOCKING CASTER 20 PUMP-ACC-17 JS/VS PUMP BRACKET 6 CLAMP-01 1/2”
24" HIGH PERFORMANCE PARTS 3$& . +396 5HYLVHG # PART # DESCRIPTION # PART # DESCRIPTION 1 BASE-2K24 CADDY 20 LOCKNUT-FNG-516 5/16-18 FLANGE NYLON INSERT LOCK NUT 2 BLADE-ASSM-02 VOSTERMAN 24” FAN BLADE ASSY. (33deg.
36" SINGLE-SPEED PARTS 3$& .
36" THREE-SPEED PARTS 3$& .
36" VARIABLE SPEED PARTS 3$& .
48" TWO-SPEED PARTS 3$& .
VARIABLE SPD WIRING DIAGRAM 22
ONE-SPEED WIRING DIAGRAM 23
TWO-SPEED WIRING DIAGRAM 24
THREE-SPEED WIRING DIAGRAM 25
FREQUENTLY ASKED QUESTIONS Q. WHAT ASSEMBLY IS REQUIRED? A. None. Portacool evaporative coolers are ready to use right out of the box. Q. HOW DO I PREPARE MY PORTACOOL PRODUCT )OR STORAGE? A. Drain the product, dry out the pads, cover the product, and store in a dry place. Q. I -UST RAN THE E9APORATI9E COOLER )OR THE )IRST TIME AND THERE’S AN UNPLEASANT ODOR! A. The pads, located in the back of your Portacool product, have never been wet before.
The manual is available in other languages. To download a digital copy, please visit www.portacool.com. CUSTOMER SERVICE CONTACT 1-936-598-5651 • 1-800-695-2942 ORDERS@PORTACOOL.COM TECHNICAL/PARTS CONTACT 1-936-598-5651 • 1-888-COOLAID SUPPORT@PORTACOOL.COM VISIT PORTACOOL.COM OR CALL 1-936-598-5651 FOR MORE INFORMATION El manual está disponible en otros idiomas. Para descargar una copia digital, por favor visite www.portacool.com. Le manuel est disponible en d’autres langues.