PORTACOOL CLASSIC OWNER’S MANUAL PAC163SVT, PAC161SVT, PAC2K36HPVS, PAC2K361S, PAC2K482S, PAC2K481S * Applies to all 120 and 240V products for global configurations
QUICK SETUP 1 2 Remove product from packaging 5 Position on level surface For setup, KUUL ComfortTM evaporative media should appear wet before starting the fan. Check the water gauge to monitor water level in tank. The water adjustment valve on each portable evaporative cooler is set at max flow. However, ensure the knob is turned completely to the right before use. Turn to the left to increase water flow.
SAFETY OPERATION WARNINGS 1) Not for use by children 2) Not for use by persons with reduced physical, sensory or mental capabilities 3) Not for use by persons who have not reviewed the owner’s manual and familiarized themselves with the operation of the product SAFE OPERATION To reduce the risk of electric shock, fire or injury: • Do not operate any evaporative cooler with a damaged cord or plug. • Do not run power cord under carpeting or cover with throwrugs, runners or similar coverings.
OVERVIEW PORTACOOL CLASSIC ™ 48” TWO SPEED Serial plate Control panel KUUL Comfort™ evaporative media Water adjustment valve Power cord with GFCI Drain valve Hose connection Casters
OVERVIEW PORTACOOL CLASSIC ™ 48” ONE SPEED *Sold only through select distributors Serial plate Control panel KUUL Comfort™ evaporative media Water adjustment valve Drain valve Power cord with GFCI Hose connection Casters
OVERVIEW PORTACOOL CLASSIC ™ 36” VARIABLE SPEED Serial plate KUUL Comfort™ evaporative media Control panel Water adjustment valve Drain valve Power cord with GFCI Hose connection Casters
OVERVIEW PORTACOOL CLASSIC ™ 36” ONE SPEED Serial plate KUUL Comfort™ evaporative media Water adjustment valve Control panel Drain valve Power cord with GFCI Hose connection Casters
OVERVIEW PORTACOOL CLASSIC ™ 16” THREE SPEED KUUL Comfort™ evaporative media Water adjustment valve Serial plate Control panel Power cord with GFCI Casters Drain located in back
OVERVIEW PORTACOOL CLASSIC ™ 16” ONE SPEED *Sold only through select distributors KUUL Comfort™ evaporative media Water adjustment valve Serial plate Control panel Power cord with GFCI Casters Drain located in back
GFCI The Portacool Classic™ series utilizes a GFCI (Grounded Fault Circuit Interrupter) to help protect users against ground electrical faults, which prevent some fire and electrical shock hazards. These devices are intended to trip at very low leakage currents. Portacool Classic models PAC2K482S, PAC2K481S, PAC2K36HPVS, PAC2K361S, PAC163SVT and PAC161SVT use a GFCI, which is built into the power cord.
START UP PLACEMENT 1) Make sure there is a clear, unobstructed path in front of the evaporative cooler to provide maximum airflow. 2) If the evaporative cooler is positioned on a raised platform, ensure the platform is stable, well constructed and will not allow the evaporative cooler to tip over. Ensure it allows for the full weight of the evaporative cooler, including a tank full of water.
MAINTENANCE While the rugged, corrosion-resistant construction ensures low maintenance will be required, keeping your evaporative cooler clean will ensure it stays in peak operating condition. DAILY MAINTENANCE The pump should be turned off approximately 15 minutes before the fan is turned off, which allows the KUUL® evaporative media to dry.
TROUBLESHOOT Turn off all power to your evaporative cooler before attempting to troubleshoot any of the following symptoms. For problems not listed, please contact Customer Service. REMEDY SYMPTOM POSSIBLE CAUSES Evaporative cooler fails to start or deliver air 1. No electricity to the evaporative cooler A. Circuit breaker tripped B. GFCI tripped C. Power unplugged or damaged 1. Check power A. Reset breaker* B. Reset GFCI** C. Plug in cord(s) or replace if damaged 2.
TROUBLESHOOT SYMPTOM POSSIBLE CAUSES REMEDY Musty or unpleasant odor 1. Stale or stagnant water in tank 1. Drain, flush and clean tank 2. KUUL evaporative media is mildewed or clogged 2. Replace KUUL evaporative media 1. Too much water delivered to KUUL evaporative media 1. Make sure KUUL evaporative media is properly positioned in the frames and evaporative cooler is level 2. Leaking hose 2. Tighten connection or replace hose Water droplets in the air stream ORDER PARTS ONLINE portacoolparts.
WARRANTY TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Portacool, LLC Customer Service at (800) 695-2942 for the distributor nearest you. You may also contact Customer Service for consultation on troubleshooting and parts replacement. Please have serial number and model number of evaporative cooler available.
PORTACOOL PROTECT Portacool, LLC is proud to provide world-class service and support. Portacool Protect™ brings together our commitment to service and support in the form of best-in-class warranties, service programs, technical support and live customer service to provide our customers with an ownership experience that is second to none.
FAQ Q. What assembly is required? A. None. Portacool Classic evaporative coolers are ready to use right out of the box. Q. How do I prepare my evaporative cooler for storage? A. Drain the evaporative cooler, dry out the evaporative media, cover the evaporative cooler and store in a dry place. Q. How often should my KUUL ComfortTM evaporative media be replaced? A. Depending on the quality of maintenance and frequency of use, KUUL Comfort evaporative media typically last up to five years.
Q. Where are the model and serial numbers found? A. The model number can be found on a metal plate on the outside of the evaporative cooler. Model numbers begin with the letters “PAC.” Serial numbers are all digits. Q. What if my questions are not answered here? A. Check out our videos on www.portacool.com or our YouTube channel. Our U.S.-based Customer Service staff is available 8 a.m. to 5 p.m. Central Time, Monday though Friday at (800) 695-2942 or you can e-mail them at support@portacool.com.
PARTS PRODUCTS SOLD IN THE UNITED STATES, CANADA AND MEXICO MOTOR PUMP MEDIA CONTROLS COVER HARD WATER TREATMENT PAC2K482S PAC2K36HPVS PAC2K361S PAC163SVT MOTOR-010-01 MOTOR-012-05 MOTOR-012-01STA MOTOR-012-04E PUMP-016-4Z PUMP-016-4Z PUMP-016-4Z PUMP-0140-1 PARKULJ27000 PARKULJ26000 PARKULJ26000 PARKULJ24000 CTRL-2SPD-01 CTRL-VS-01 CTRL-1SPD-01 CTRL-3SPD-02 PAC-CVR-03 PAC-CVR-01 PAC-CVR-01 PAC-CVR-04 PARPACHWTB00 PARPACHWTB00 PARPACHWTB00 PARPACHWTB00 Additional parts can be fo
NOTES
NOTES
NOTES
NOTES
CUSTOMER SERVICE CONTACT 1-936-598-5651 • 1-800-695-2942 SUPPORT@PORTACOOL.COM TECHNICAL/PARTS CONTACT 1-936-598-5651 • 1-800-695-2942 SUPPORT@PORTACOOL.COM VISIT PORTACOOL.COM The manual is available in other languages. To download a digital copy, please visit www.portacool.com. El manual está disponible en otros idiomas. Para descargar una copia digital, por favor visite www.portacool.com. Le manuel est disponible en d’autres langues.