Fan User Manual
BRONZE PUMP (PAC2K36EP or PAC2K48EP)
SHAFT TYPE PUMP (16” models)  
  PROBLEM  CHECK  SOLUTION
 Pump motor will not run when  Power cord,  Reconnect power, 
  switch is turned on.  switches, circuit breaker, etc.  reset breaker. 
  Pump motor hums when  Object jammed into  Remove object. 
  switch is turned on,  impeller blade.  Prime pump.
  but does not 
  pump water.  Air Locked.  Replace
    Pump/Motor locked.  pump/motor. 
  Pump makes loud noise  Pump bearings.  Replace pump. 
  while running  Object in impeller housing.  Clear object.
  Breaker trips or fuse blows  Pump motor locked.  Replace pump/motor. 
  when switch is turned on. 
  Pump will not run and power Switch making closure contact.  Replace switch. 
  is available and pump 
  is functional
  Pump motor running but  Set screws on coupling.  Tighten set-screw / 
  pump is not turning.    Replace coupling. 
  PROBLEM  CHECK  SOLUTION
  Pump motor will not run  Power cord,  Reconnect power 
  when switch is turned on.  switches, circuit breaker,  cord, reset breaker.
    switch box, connections, etc.  or reconnect to switch box.
  Pump motor hums when  Object jammed into impeller blade.   Remove object.
  switch is turned on, but  Air Locked.  Prime pump. 
  does not pump water.  Check disc that covers impeller  Attach disc securely
    Pump motor locked.  Replace pump. 
  Pump makes loud noise  Pump bearings.  Replace pump. 
  while running. 
Object in impeller housing.  Clear object. 
 Breaker trips or fuse blows  Pump motor locked.  Replace pump. 
  when switch is turned on.
 Pump won’t run and power  Switch making closure contact.  Replace switch.
  is available and 
  pump is functional.
27
2007 PORT-A-COOL® Unit Electric Models
14