Fan User Manual
13
2007 PORT-A-COOL® Unit Electric Models
28
2007 PORT-A-COOL® Unit Electric Models
SPRAY BAR ASSEMBLY (ALL MODELS) 
SUBMERSIBLE PUMPS PROBLEM CHECK SOLUTION  
  PROBLEM  CHECK  SOLUTION
 Too many dry streaks in the pads.  Holes in spray bar blocked   
Remove and clean spray bar.
    by foreign material. 
Clean individual holes. 
  Water spitting from the unit.  Hose connection loose.   Tighten hose. 
      Replace hose and washer. 
      Reseat spray bar end caps 
  Excess water in air  Pad Installation  Pads must be installed
  coming from the fan.    according to air flow
      direction label on the pad.
  PROBLEM  CHECK  SOLUTION
 Pump will not run when switch  Power cord, switches,  Reconnect power,  
  is turned on.   circuit breaker,  reset breaker
    switch box, connection, etc.  or reconnect in switch box.
    Air lock in hose.  Disconnect hose at base of
      pump, run pump to release 
      air, then reconnect.
  Pump hums when switch is  Inlet filter clogged.  Clean filter.  
  turned on, but does not  Pump motor locked.  Replace pump.
  pump water.  Other items on circuit.  Remove other items.
  Breaker trips or fuse blows   Wiring short in line between  Check and/or replace wiring. 
  when switch is turned on.  pump and switch box. 
  Pump cycling on and off  Sump tank is empty.  Fill with water. 
  periodically  Spray bar valve is closed.  Open valve. 
 Pump will not run and power is   Switch making closure contact.  Check continuity/ 
 available and pump is functional.    Replace switch.