SDS
Safety Data Sheet
According to Regulation (EU) No. 1907/2006 (REACH), Annex II
(COMMISSION REGULATION (EU) No 453/2010)
Version: 1.0/EN Revision date: 27/02/2012
Product name: Glutex Printing date: 27/02/2012
-- Page 5 / 10 --
Store in a locked cabinet or with access restricted to technical experts or their assistants.
Package: 1.5g、3g、5g、6g、7g、10g、12g、15g、30g、60g、120g in alumimun tube and sealed.
7.3 Specific end use(s)
Apart from the uses mentioned in SECTION 1.2 no other specific uses are stipulated.
SECTION 8 : Exposure controls/personal protection
8.1 Control parameters
Exposure limit values:
CAS# 78
-
93
-
3
MAC (NL): 200 ppm; 590 mg/m3.
MAK (DE): 200 ppm; 590 mg/m3.
WEL (UK): 200 ppm; 590 mg/m3.
TWA (US OSHA): 200 ppm; 300 ppm (STEL).
TWA (ACGIH): 200 ppm; 300 ppm (STEL).
CAS# 67
-
64
-
1
MAC (Japan): 200 ppm; 470 mg
/m3.
MAC (NL): 750 ppm; 1780 mg/m3.
MAK (DE): 1000 ppm; 2400 mg/m3.
TWA (US OSHA): 750 ppm; 1000 ppm (STEL).
TWA (ACGIH): 750 ppm; 1000 ppm (STEL).
CAS# 141-78-6 MAC (NL): 550 mg/m
3
.
WEL (DE): 400 ppm; 1400 mg/m
3
.
TWA (UK): 200 ppm; 400 ppm (STEL).
TWA (US OSHA): 400 ppm.
TWA (ACGIH): 400 ppm.
DNEL (Derived No Effect Level) for workers and the general population:
Not available.
PNEC (Predicted No Effect Concentration) values:
Not available.
8.2 Exposure controls
Appropriate engineering contro
ls:
Use adequate general or local exhaust ventilation to keep airborne concentrations below exposure limits.
The usual precautionary measures should be adhered to in handling the chemicals. Instantly remove any
soiled and impregnated garments. Avoid contact with skin and eyes and the inhalation of vapor.
Personal protective equipment:
Eye protection:
Wear appropriate protective eyeglasses or chemical safety goggles.
H
and
protection:
Wear appropriate protective gloves to prevent hand exposure.
Wash hands before breaks and at end of work
Skin protection:
Wear appropriate protective clothing to prevent skin contact.