User manual
11
- GB -
Cleaning the filter pump (F)
Take pump out of the water, unscrew the stepped hose connection including the O ring from the connection thread,
actuate the engagement hook of the filter housing, open the filter housing and remove the pump. Turn off the pump
housing, remove the impeller. Clean the pump housing, the impeller and the filter housing using clear water and a
brush. After cleaning, fit the unit in the reverse order.
Pos: 50 /Filter/Pond oClear Set/Lagern PondoC lear @ 2\mod_113714292 6365_121.doc @ 13000
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the flow-through filter, check for damage. Remove, clean, dry and store all filters
in a frost-free environment. Store the filter pump submerged or filled in a frost-free environment. Do not immerse the
plugs! Ensure that the storage place is inaccessible to children. Cover the filter container such that the ingress of rain
water is excluded. Drain all hoses, pipes and connections as far as possible.
Pos: 51 /Filter/Pond oClear Set/Verschleiß teile PondoClear @ 2\ mod_1137142941722_121. doc @ 13100
Wearing parts
The UVC lamp, the quartz glass, the filters and the rotor are wear parts and are excluded from the warranty.
Pos: 52 /Alle Produkte/ Entsorgung mit UVC @ 2\mod_1 137146293332_121. doc @ 13332
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special disposal. Ask your
specialist dealer.
Pos: 53 /Filter/Pond oClear Set/Störung Pon doClear @ 2\mod_11371429 38294_121.doc @ 13075
Malfunctions
Malfunction Cause Remedy
Unit has been in operation only for a short time The complete biological cleaning effect is only
achieved after several weeks
Water extremely soiled Remove algae and leaves from the pond,
perform a partial water change
Excessive fish and animal population Guide value: approx. 60 cm fish length in 1 m³
pond water
Foam filters soiled Clean filters
Pump filter housing soiled Clean pump filter housing
Impeller unit blocked Clean pump
Quartz glass tube soiled Remove UVC and clean quartz glass
The unit performance is not satisfactory
UVC lamp capacity exhausted Replace the lamp after approx. 8,000 operating
hours
Power supply of UVC not connected Connect UVC power plug
UVC lamp defective Replacing the UVC lamp
Connection defective Check electrical connection
UVC lamp display is not lit
UVC overheated UVC automatically switches on when cooled
down
Pump power supply not connected Connect pump power supply No water outlet from the pond inlet
Pond inlet blocked Clean pond inlet
Pos: 54 /Alle Produkte/ Garantie 2 Jahre @ 0\mod_1125 578641343_121.doc @ 1431
Guarantee conditions
PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer’s claims against the dealer.
Pos: 55 /Alle Produkte/ Dummy_module/=== == Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630