User's Manual
Chapter 6 - Testing and Troubleshooting
© Polycom, Inc. 113
Fault Isolation
The following table lists symptoms, causes, and corrective actions 
for equipment malfunctions.
Table 6-6. Fault Isolation
Problem Possible cause Corrective action
Monitor screen remains blank Monitor is not connected to 
power
Check all cables to equipment
Monitor is not connected to 
endpoint equipment
Endpoint equipment is not 
connected to power
System is in sleep mode Lift the remote control and point 
it toward the remote sensor
Reboot process does not end Flash memory is full Turn off power to the system, 
then press and hold the reset 
switch while turning on power
Reboot process halts without 
finishing
File corruption Turn off power to the system, 
then press and hold the reset 
switch while turning on power
System displays a Softupdate 
screen
No power at PRI network 
interface module
Check cable between endpoint 
and PRI network interface 
module
PBX does not accept calls of 
numbering type “unknown” 
from PRI network interface 
module
Configuration problem Refer to the appropriate User 
Guide for information about 
configuring the PRI