User's Manual
It is also possible to use the wildcard character ('*') to specify ranges of crosspoints with the matrix 
commands. The only restriction is that you can only use a wildcard to specify the input or output, but 
not both simultaneously. Thus you could specify all the inputs going to a specific output (one column) 
or the value of an input to all of the outputs (one row), but not the entire matrix. One example of 
using a wildcard for an integer matrix command would be ' S04MGAINSG,*,0 '. This will set all the 
crosspoints in the signal generator row of the main matrix to 0 dB. Thus, the signal generator will be 
added to all of the outputs of the main matrix with a gain of 0 dB. In this case a status message will 
be generated that looks like ' S04MGAINSG,*,ääääääääää '. The binary representation used here is 
the same method described in 
Section 6.3. 
You can also use the wildcard character to set the crosspoints of a row or column individually. For 
example, 'S04MGAIN1,*,äzzzxxxxxx' sets the crosspoints of input 1 to 0 dB for output 1, -10 dB 
for outputs A, B and T, and -12 dB for outputs R1, P, and W-Z. In this case, the EF2211 will respoind 
with a status message of 'S04MGAIN1,*,äzzzxxxxxx'. 
Queries using the '?' character work in the usual manner. For example, ' S04MGAIN1,A,? ' might 
return ' S04MGAIN1,A,-6 ', while ' S04MGAIN1,*,? ' might return ' S04MGAIN2,*,ääääääääää '. 
Boolean matrix commands work as you would expect. They use the characters '0', '1', and '2' as 
described in 
Section 6.1. Here are some examples. 
● ' S04MMUTE1,A,1 ' mutes crosspoint (1, A) of the main matrix. In other words, the signal at 
input 1 will not be heard on output A A status message will be generated of the form ' 
S04MMUTE1,A,1 '. 
● 'S04MMUTEA,*,1110000000' sets the mutes for input A of the main matrix. The signal path 
from input A to outputs 1, A, and B is muted, while the signal path from input A to outputs T, 
R1, P, and W-Z is unmuted. The EF2211 will respond with a status message of 
'S04MMUTEA,*,1110000000'. 
● 'S04MMUTEA,*,2' toggles the mutes for input A of the main matrix. If this command follows 
after the command in the above example, the EF2211 will respond with a status message of 
'S04MMUTEA,*,0001111111'. 
● 'S04MMUTEA,*,?' queries the status of the mutes for input A of the main matrix. If this 
command follows after the commands in the above examples, the EF2211 will respond with a 
status message of 'S04MMUTEA,*,0001111111'. 
6.5. Miscellaneous Commands
Miscellaneous commands are those that don't fall under any of the other categories. See the 
description of a given command for specific details on how it operates. 
7. Command List
The following table is a list of the commands recognized by the EF2211 Detailed descriptions of each 
command are given in the next section. 