User's Manual
SpectraLink 8002 Wireless Telephones Configuration and Administration (SIP) 
80  PN: 1725-36034-001_C.doc 
The table below lists the syslog messages and which level of logging 
will produce them: 
Message type  Errors  Events  Full 
Failed Handoff  Yes Yes Yes 
Successful Handoff  No  Yes  Yes 
Security Error  Yes Yes Yes 
Call Start/End  No  Yes  Yes 
Audio stats  No  No  Yes (every 5 secs) 
Audio error threshold exceeded  Yes  Yes  Yes 
Radio stats  No  No  Yes (every 5 secs) 
Radio error threshold exceeded  Yes  Yes  Yes 
All syslog messages will include: 
•  Date and time (to 1/100th of second) since handset power on 
(currently set to Jan-1 00:00.00) 
•  Handset’s MAC address 
•  Handset’s IP address 
•  Syslog sequence number 
The table below lists the additional items in each message type: 
Failed Handoff 
(Sent whenever the handset attempted to 
handoff, but failed trying.) 
Failed AP MAC 
Failed AP signal strength 
Current AP MAC 
Current AP signal strength 
Failure reason 
Successful Handoff  New AP MAC 
New AP signal strength 
Old AP MAC 
Old AP signal strength 
Reason for handoff 
Other candidate APs: 
MAC 
Signal strength 
Reason not used 
Security Error  AP MAC 
AP signal strength 
Security mode 
Error details (mode dependent) 