User manual
Polycom RMX 2000 Administrator’s Guide 
C-23
Table C-8  Event Fields for Event 2 - CONFERENCE END
Field Description
Conference End 
Cause
Indicates the reason for the termination of the 
conference, as follows:
1 - The conference is an ongoing conference or the 
conference was terminated by an MCU reset.
2 - The conference was terminated by a user.
3 - The conference ended at the scheduled end time.
4 - The conference ended automatically because no 
participants joined the conference for a predefined time 
period, or all the participants disconnected from the 
conference and the conference was empty for a 
predefined time period.
5 - The conference never started.
6 - The conference could not start due to a problem.
8 - An unknown error occurred.
9 - The conference was terminated by a participant using 
DTMF codes.
Table C-9  Event fields for Event 3 - ISDN/PSTN CHANNEL 
CONNECTED
Field Description
Participant Name The name of the participant.
Participant ID The identification number assigned to the participant by 
the MCU.
Channel ID  The channel identifier. 
Number of 
Channels
The number of channels being connected for this 
participant.
Connect Initiator Indicates who initiated the connection, as follows:
0 - RMX
1 - Participant
Any other number - Unknown