Specifications

Table Of Contents
Integrator’s Reference Manual for Polycom HDX Systems
4–144 Polycom, Inc.
gatewayprefix
Sets or gets the gateway prefixes for the corresponding speeds.
Syntax
gatewayprefix get “valid speed”
gatewayprefix set “valid speed” [“value”]
Feedback Examples
gatewayprefix set 168 90
returns
gatewayprefix 168 90
gatewayprefix get
168
returns
gatewayprefix 168 90
Comments
Some gateways require a number to be prepended (prefix) to the gateway
number. The prefix identifies which gateway is used to dial a call at a
particular data rate.
Parameter Description
get
When followed by the
“valid speed
parameter,
returns the current value for this speed.
“valid speed”
Valid speeds are: 56, 64, 2x56, 112, 2x64, 128, 168,
192, 224, 256, 280, 320, 336, 384, 392, 7x64, 8x56,
504, 512, 560, 576, 616, 640, 672, 704, 728, 768, 784,
832, 840, 16x56, 14x64, 952, 960, 1008, 1024, 1064,
1088, 1120, 1152, 1176, 1216, 1232, 1280, 1288,
24x56, 21x64, 1400, 1408, 1456, 1472, 1512, 1536,
1568, 1600, 1624, 1664, 1680, 1728, 1736, 32x56,
28x64, 1848, 1856, 1904, and 1920 kbps.
set
Sets the gateway prefix when followed by the
“value”
parameter. To erase the current setting, omit
“value”
.
“value”
Prefix (code) used for a particular call speed. Consult
your gateway instruction manual to determine which
codes are appropriate.