dsr
Sets or gets the configuration of the DSR serial interface control signal (data set
ready). This command is only applicable if you have a V.35 network interface
connected to your system.
Syntax
dsr <get|normal|inverted>
Feedback Examples
dsr normal
returns
dsr normal
dsr inverted
returns
dsr inverted
dsr
get
returns
dsr inverted
Comments
The default setting for this signal is
“normal”
.
Parameter Description
get
Returns the current setting.
normal
Sets the signal to normal (high voltage is logic 1).
inverted
Sets the signal to inverted (low voltage is logic 1).