Specifications

Table Of Contents
Integrator’s Reference Manual for Polycom HDX Systems
4–94 Polycom, Inc.
notification:callstatus:outgoing:45: Polycom Austin:
192.168.1.101:connected:384:0:videocall
Note: The call ID number (45) is an example of the response.
The Call ID number depends upon the call type.
Comments
When searching for feedback from the dial command, expect to see the set of
described strings as many times as there are channels in the call.
When initiating a multipoint call or adding multiple sites to a multipoint call
over ISDN, you must be sure that the total call rate does not exceed the
bandwidth of the ISDN interface. Otherwise, one of the calls may not connect.
For example, the total ISDN bandwidth for a T1 line is 1544 kbit/s. Thus,
making the following five calls in succession violates the ISDN bandwidth
rule, because the total ISDN bandwidth would require 1920 kbit/s (1920 =
384 * 5), and one of the calls may not connect:
dial manual 384 5551212
dial manual 384 5561212
dial manual 384 5571212
dial manual 384 5581212
dial manual 384 5591212
Similarly, making the following two calls in a multipoint call where sites 1, 2,
and 3 are already connected at 256 kbits/s each violates the ISDN bandwidth
rule. This is because the total ISDN bandwidth required becomes 1792 kbits/s
(1792 = 256 * 3 + 512 * 2), and one of these two new calls may not connect:
dial manual 512 5581212
dial manual 512 5591212
Note: The ISDN bandwidth rule is not applicable to IP calls and only applies
when multiple ISDN dial commands are issued in succession without waiting
for the active call notification (i.e., active: call[36] speed[128]) between dial
commands. Adding single calls to a multipoint call and then waiting for the
active call notification does not break the rule, because the system downspeeds
calls to meet the required ISDN bandwidth limitations.
See Also
Refer to the callstate command on page 4-64 . You can use callstate register to
obtain updated information on the status of a call. For example, when using
the dial manual to place a call, callstate register can tell you when the call is
connected.