Specifications

Integrator’s Reference Manual for Polycom HDX Systems
4 - 156
mute
Sets or gets the near or far site mute settings.
Syntax
mute <register|unregister>
mute near <get|on|off|toggle>
mute far get
Feedback Examples
mute near on
mute registered
mute unregistered
mute near off
mute far on
or
mute far off
(returned from
mute far get
or when system is
registered to receive mute states)
Comments
In register mode, the system sends notification to the API session when the far
or near site is muted or unmuted.
Parameter Description
register
Registers to receive notification when the mute mode
changes.
unregister
Disables register mode.
near
Sets the command for the near site. Requires
on
,
off
,
toggle
, or
get
.
get
Returns the current setting for the near or far site.
on
Mutes the near site (
mute near on
).
off
Unmutes the near site (
mute near off
).
toggle
If mute near mode is
mute near on
, this switches to
mute near off
, and vice versa.
far
Sets the command for the far site. Requires the
parameter
get
.