Parameter
Permitted Values
Default
lineKey.reassignment.enabled
0, 1
0
Enables the line key reassignment feature—Flexible Line Key.
lineKey.x.index
0, 1, 2
0
Specifies which index is used to pick up the line key x, within the specified category, and assigned to the line key.
Depends on the lineKey.x.category parameter.
<efk/>
Use the following three tables to configure the enhanced feature key feature on your phone.
Enhanced Feature Key (EFK) Parameters
Parameter Name
Permitted Values
Default
efk.version
2 (1 for SIP 3.0 and
earlier)
2
The version of the EFK elements. For SIP 3.0.x or earlier, 1 is the only supported version. For SIP 3.1 and later,
2 is the only supported version. If this parameter is Null, the EFK feature s disabled. This parameter is not
required if there are no efk.efklist entries.
The EFK list parameters are outlined in the following table.
Enhanced Feature Key (EFK) List Parameters
Parameter Name
Permitted Values
Default
efk.efklist.x.action.string
The action string contains a macro definition of the action that the feature key will perform. If EFK is enabled, this
parameter must have a value (it cannot be Null). For a list of macro definitions and example macro strings, see
Understanding Macro Definitions in the Polycom UC Software 4.1.0 Administrator’s Guide.
efk.efklist.x.label
string
Null
The text string that will be used as a label on any user text entry screens during EFK operation. If Null, the Null
string is used. Note: If the label does not fit on the screen, the text is shortened and ellipses (…) is appended.
efk.efklist.x.mname
expanded_macro
The unique identifier used by the favorites configuration to reference the enhanced feature key entry. Cannot
start with a digit. Note that this parameter must have a value, it cannot be Null.
efk.efklist.x.status
0 or 1
0
If 0 or Null, key x is disabled. If 1, the key is enabled.