Users Manual
SME VOIP SYSTEM GUIDE 1.1 66 | P a g e
Proprietary and Confidential
To be compliant with IEEE1588, this port must be default value.
Before setup, make sure no other devices are using the given IP.
NOTE: This should only be changed in case other IEEE1588 equipment is on the
network and using this specific IP address.
MULTICAST
PORT
319 Define the port which the system will listen for IEEE1588 PTP messages
To be compliant with IEEE1588, this port must be default value.
NOTE: This should only be changed in case other IEEE1588 equipment is on the
network and using this specific port.
DOMAIN
NUMBER
1 The domain number is a preferred method to divide the IEEE1588 PTP
messages into zones in IEEE 1588-2008.
Note: The input must NOT be the same as the one used in the previous feature
“Zone LAN sync setup”
ALTERNATIVE
DOMAIN
NUMBER
65 Alternative domain is only used in case the primary sync source from the main
domain fails. If so, the base station will sync with the alternative domain.
Note: The input must NOT have the same value as the “Domain number” from
the previous parameter and must NOT be used in the “Zone LAN sync setup”
feature.
Base station group
The Base station group lists various parameter settings for the Base stations and allows the user to check the status
information for the whole system.
Screenshot:
PARAMETERS DESCRIPTION
ID Base unit identity in the chained network.
Permitted Output: Positive Integers
STATUS Base station characteristics in connection to the current Multi cell network.
Possible Output(s)
Primary: Main Base station into which all other nodes in the chain synchronize to.
Locked: The Base unit is currently synchronized and locked to the master Base unit.
Searching: Base unit in the process of locating a Master/Slave as specified in DECT sync
source
Free Running: IEEE master is found, and is DECT synchronizing
PREFERED ROLE Disabled: Disable the feature
Primary: The Base station that is used for main sync; only one primary is allowed to the
system
NOTE: It is recommended to use Base stations that are closer to the backbone as primary
Secondary: Base stations that will never be selected as primary. They become slaves
Automatic: System finds primary sync source – it allows the system to decide the role of
the base
Alt. Primary: Backup for primary Base station in case it fails; only one redundant sync.
master is allowed in the system