Users Manual

SME VOIP SYSTEM GUIDE 1.1 70 | P a g e
Proprietary and Confidential
Repeaters list
Screenshot
The number of repeaters allowed on each Base station is defined on the Multi cell page.
System combination: 50/3 – 127/1 -254/0 (please visit chapter 5.12.3 for more details).
If the system combination is set to 127/1 or 254/0, you can still register more than one repeater, but it will not get a
DECT Sync source and will have no function.
Example:
System combination 50/3:
Base stations are named RPN00 – RPN04 – RPN08. Etc. jumping 4 numbers each time (HEX numbers)
Repeaters connect to Base station RPN00 will be called RPN01 – RPN02 – RPN03 (HEX numbers)
Repeaters connect to Base station RPN04 will be called RPN05 – RPN06 – RPN07 (HEX numbers)
Etc.
System combination 127/1:
Base stations are named RPN00 – RPN02 – RPN04. Etc. jumping 2 numbers each time (HEX numbers)
Repeaters connect to Base station RPN00 will be called RPN01 (HEX numbers)
Repeaters connect to Base station RPN02 will be called RPN05 (HEX numbers)
Etc.
System combination 254/0:
Repeater registration not possible
PARAMETERS DESCRIPTION
IDX Repeater unit identity in the chained network.
Permitted Output: Positive Integers
RPN The Radio Fixed Part Number is an 8-bit DECT cell identity allocated by the installer. The
allocated RPN within the SME must be geographically unique.
Permitted Output:
0 to 255 (DEC)
OR
0x00 to 0xFF (HEX)
NAME/IPEI Contains the name and the unique DECT serial number of the repeater. If name is given
the field will be empty.
DECT SYNC
SOURCE
The “multi cell chain” connection to the specific Base/repeater unit. Maximum number of
chain levels is 12.
Sync. source format: “RPNyy (-zz dBm)”
yy: RPN of source
zz: RSSI level seen from the actual repeater
DECT SYNC MODE Manually: User controlled by manually assign “Repeater RPN” and “DECT sync source
RPN”