Operation Manual
LECOASPIRA PROGRAM
63
Periodically check the status of the coloured washer located in the built-in socket (A6). If necessa-
ry, replace with the corresponding spare part (P), as described below.
Perform the same check on the connection seals of the extension tubes (B and B1) and the han-
dle (A2). If necessary, modify as follows.
Fig. I
- Remove the damaged washer.
- Insert the new washer, placing it on the steam nozzle and pushing it
until it is in its place. See (Fig. I)
- Lubricate the gasket with silicone grease or Vaseline, or alternatively
with small quantities of vegetable oils.
Fig. H
- Remove the damaged washer.
- Insert the new washer, placing it on the steam nozzle and pushing it
until it is in its place. See (Fig. H)
- Lubricate the gasket with silicone grease or Vaseline, or alternatively
with small quantities of vegetable oils.
HOW TO REPLACE THE SEALS (P)
ENGLISH
LECOASPIRA PROGRAM - M0S10133 - 1T10:Layout 1 23/10/2013 9.45 Pagina 63