Operation Manual
| 35 |
Should the problems persist, contact an Authorised Polti Service Centre (see www.polti.com for the up-to-date list) or
Customer Services.
PROBLEM CAUSE SOLUTION
Accessories are difficult to assemble
The seals produce friction
The locknut is not in the correct
position
Lubricate the seals with silicone grease or
Vaseline, or alternatively with a small amount
of vegetable oil.
Turn the locknut to the correct position
After vacuuming liquids, the liquid
vacuumed comes out of the brush
Liquid remains inside the tubes
Floor is still not dry
Suck in air for a few seconds to allow the
transfer of the liquid to the tank
Repeat the vacuuming operation
The filling pump of the boiler continues to
operate.
There is air in the boiler circuit.
Switch off the appliance and let it cool, after
which repeat the operations described in
chapter 1.
The appliance turns off while using suc-
tion
Water filter collector full or
motor overheated
Turn off anddisconnect the appliance from
the mains. Empty the dirt collector and clean
it. If the problem persists, turn off and discon-
nect the appliance from the mains and wait
60 minutes for it to cool.
The appliance stops and the wording “E1”
appears on the display
The circuit board has detected a
fault in the boiler.
Turn the appliance off for a few minutes and then
start it again. Should the problem occur again,
contact an Authorised Service Centre.
The appliance stops and the wording “E2”
appears on the display
The circuit board has detected a
fault relative to incorrect operating
temperature.
Turn the appliance off for a few minutes and
then start it again. Should the problem occur
again, contact an Authorized Service Centre.
The maintenance indicator lights up on the
display
The appliance does not warm up
correctly.
Turn the appliance off for a few minutes and
then start it again. Should the problem occur
again, contact an Authorized Service Centre.
ENGLISH