Operation Manual
VAPORELLA FOREVER 1905 ECO PROGRAM
31
ENGLISH
CARE OF YOUR VAPORELLA
• Before attempting any maintenance opera-
tion, always disconnect the appliance
from the mains.
• To clean the body of the appliance, simply
use a moist cloth. Do not use solvents or de-
tergents which may harm the body material.
CLEANING THE BOILER
• Disconnect the appliance and let it cool down
for at least 2 hours.
• Empty the water tank to prevent leakage.
• Turn the appliance upside-down and use the
hexagon wrench (13) to unscrew the boiler
cap (12) on the bottom of the appliance
(fig.7).
• Use the funnel (14) to pour 250 ml of cold wa-
ter into the boiler.
CAUTION: do not pour more than the spe-
cified amount of water into the boiler. Pour
water slowly, being careful not to let it
overflow, as this could damage the ap-
pliance (fig.8).
• Rinse out the boiler and pour the water away
into the sink or into a container for collecting
dirty water.
• If the water is very dirty, repeat the operation
until it is clean.
• Before screwing the boiler cap (12) back on,
pour 100 ml of water in.
Do not operate the equipment again with
the boiler empty.
• Put the cap back on the boiler, checking that
the seal is present and that the cap is
screwed on properly.
• Fill the water tank again and put the cap on.
• Turn the appliance on again.
• Before ironing, release steam into the sink or
another container and check that the steam is
clean. This should take a few seconds.
• Resume ironing normally.
• To maintain optimum performance, clean the
boiler every 10/20 uses depending on the
amount of limestone in the water.
VL FOREVER 1905 ECO P. M0S10166 1S02_7:FEV 1000-950.qxd 09/03/2012 9.52 Pagina 31