ENGLISH
CARE OF YOUR VAPORELLA
Before attempting any maintenance opera-
tion, always disconnect the appliance
from the mains.
To clean the body of the appliance, simply
use a moist cloth. Do not use solvents or de-
tergents which may harm the body material.
CLEANING THE BOILER
Disconnect the appliance and let it cool down
for at least 2 hours.
Empty the water tank to prevent leakage.
Turn the appliance upside-down and use the
hexagon wrench (13) to unscrew the boiler
cap (12) on the bottom of the appliance
(fig.7).
Use the funnel (14) to pour 250 ml of cold wa-
ter into the boiler.
CAUTION: do not pour more than the spe-
cified amount of water into the boiler. Pour
water slowly, being careful not to let it
overflow, as this could damage the ap-
pliance (fig.8).
Rinse out the boiler and pour the water away
into the sink or into a container for collecting
dirty water.
If the water is very dirty, repeat the operation
until it is clean.
Before screwing the boiler cap (12) back on,
pour 100 ml of water in.
Do not operate the equipment again with
the boiler empty.
Put the cap back on the boiler, checking that
the seal is present and that the cap is
screwed on properly.
Fill the water tank again and put the cap on.
Turn the appliance on again.
Before ironing, release steam into the sink or
another container and check that the steam is
clean. This should take a few seconds.
Resume ironing normally.
To maintain optimum performance, clean the
boiler every 10/20 uses depending on the
amount of limestone in the water.
VL FOREVER 1905 ECO P. M0S10166 1S02_7:FEV 1000-950.qxd 09/03/2012 9.52 Pagina 31