Data Sheet

DocID031281 Rev 2 17/35
VL53L1X Ranging performances
35
3.5 Performances in ambient light conditions
3.5.1 Long distance mode
Test conditions (including those described in Section 3.1: Test conditions) are:
Ambient light = dark, 50 kcps/SPAD, 200 kcps/SPAD
Distance mode = long
3.5.2 Short distance mode
Test conditions (including those described in Section 3.1: Test conditions) are:
Ambient light = dark, 200 kcps/SPAD
Distance mode = short
Table 7. Typical performances in ambient light with long distance mode
Parameter Target reflectance Dark 50 kcps/SPAD 200 kcps/SPAD
Max. distance (cm)
White 88 % 360 166 73
Grey 54 % 340 154 69
Grey 17 % 170 114 68
Ranging error (mm) ± 20 ± 25 ± 25
Table 8. Typical performances in ambient light conditions with short distance mode
Parameter Target reflectance Dark 200 kcps/SPAD
Max. distance (cm)
White 88 % 130 130
Grey 54 % 130 130
Grey 17% 130 120
Ranging error (mm) ± 20 ± 25