Data Sheet

TB67S279FTG
2017-09-15
22
AC electrical characteristics (Ta = 25°C and VM = 24 V, unless otherwise specified)
Characteristics Symbol Test condition Min Typ. Max Unit
Minimum CLK ‘High’ pulse width tCLK (H)
CLK (H) minimum pulse width 500 ns
Minimum CLK ‘Low’ pulse width tCLK (L)
CLK (L) minimum pulse width 500 ns
Output MOSFET switching
specifications
tr
30 80 130 ns
tf
40 90 140 ns
tpLH (CLK) CLK to OUT 1000 ns
tpHL (CLK) CLK to OUT 1500 ns
OSCM oscillator accuracy
ΔfOSCM1
COSC=270 pF, ROSC=5.1 kΩ
-15 +15 %
ΔfOSCM2
COSC: GND short,
ROSC: Open
-20 +20 %
PWM chopping frequency
fchop1
COSC=270 pF, ROSC=5.1 kΩ
67 kHz
fchop2
COSC: GND short,
ROSC: Open
57 kHz
AC characteristics timing chart
The timing chart may be simplified for explanatory purpose.
tCLK(H)
Motor output [OUT]
Logic input [CLK]
tpHL(CLK)
tr
tCLK(L)
tpLH(CLK)
tf