Data Sheet
TB67S279FTG,  TB67S289FTG,  TB67S249FTG  Application Note 
                       2018-03-07 
10 / 33 
Preliminary 
8.4. RESET function 
This function initializes the internal electrical angle. The standby mode can be configured by 
setting DMODE0, DMODE1, and DMODE2 pins low level. 
Note: Built-in digital filter of 0.625 μs (±20 %) is adopted to RESET pin. 
RESET  Function 
High  Initializes the internal electrical angle 
Low  Normal operation 
When the electrical angle is initialized by setting RESET pin to high level, the relation of the 
current setting for each H-bridge (Ach and Bch) and the electrical angle is shown below. In the 
case the MO pin level is pulled up, it shows low level (internal open-drain MOSFET turns on) 
when the electrical angle is initialized. 
Step resolution  Ach current  Bch current  Electrical angle 
1/32 step setting  71%  71%  45° 
1/16 step setting  71%  71%  45° 
1/8 step setting  71%  71%  45° 
Half (b) step setting  71%  71%  45° 
Quarter step setting  71%  71%  45° 
Half (a) step setting  100%  100%  45° 
Full step setting  100%  100%  45° 