Data Sheet
Enable input averaging
Offset 0x2E
Type unsigned 8-bit
Data
• 0: false
• 1: true
Default true
Settings file input_averaging_enabled
Settings file data false or true
Tic Control Center Input and motor settings tab, Input conditioning box, Enable input averaging
This setting enables RC/analog input averaging as described in Section 5.2.
Input hysteresis
Offset 0x2F
Type unsigned 16-bit
Default 0
Range 0 to 65535
Settings file input_hysteresis
Tic Control Center Input and motor settings tab, Input conditioning box, Input hysteresis
This setting specifies the amount of hysteresis to apply to RC/analog inputs, as described in Section
5.2.
Tic Stepper Motor Controller User’s Guide © 2001–2018 Pololu Corporation
6. Setting reference Page 91 of 150