Data Sheet

Register description LPS25HB
38/50 DocID027112 Rev 4
The device features one set of programmable interrupt sources (INT) that can be configured
to trigger different pressure events. Figure 19 shows the block diagram of the interrupt
generation block and output pressure data.
The device may also be configured to generate, through the INT_DRDY pin, a Data Ready
signal (DRDY) which indicates when a new measured pressure data is available, thus
simplifying data synchronization in digital systems or optimizing system power consumption.
Figure 19.
Interrupt generation block and output pressure data
8.9 CTRL_REG4 (23h)
Interrupt configuration
76543210
0000F_EMPTYF_FTH F_OVR DRDY
F_EMPTY FIFO empty flag on INT_DRDY pin. Default value: 0.
(0: disable; 1: enable)
F_FTH FIFO threshold (watermark) status on INT_DRDY pin to indicate that FIFO is filled
up to the threshold level. Default value: 0.
(0: disable; 1: enable)
F_OVR FIFO overrun interrupt on INT_DRDY pin to indicate that FIFO is full in FIFO mode
or that an overrun occurred in Stream mode. Default value: 0.
(0: disable; 1: enable)
DRDY Data-ready signal on INT_DRDY pin. Default value: 0.
(0: disable; 1: enable)