Datasheet

Broadcom ACHS-7124-7125-DS101
6
ACHS-7124/7125 Data Sheet
Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 3 kV
RMS
Isolation and
Low-Resistance Current Conductor
Recommended Operating Conditions
Primary Power Derating Curve for ACHS-7125
NOTE: Mounted on Broadcom’s Evaluation Board as shown in Figure 16 and Figure 17.
Parameter Symbol Min. Max. Units
Ambient Operating Temperature T
A
–40 110 °C
Supply Voltage V
DD
4.5 5.5 V
Output Capacitance Load C
LOAD
—10nF
Output Resistive Load R
LOAD
4.7 kΩ
Input Peak Current Range ACHS-7124 I
p
–40 40 A
ACHS-7125
a
a. Due to the SO-8 package power dissipation limitations, the input peak current is valid up to 85°C ambient temperature only on 4-oz copper
PCB. For >85°C ambient, derating is needed. For details, refer to footnote a at Absolute Maximum Ratings. For Input Power Derating Curve,
refer to the curve as shown in the following section.
–50 50 A
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
-40 -20 0 20 40 60 80 100
Pin(W)
T
A
C)
1.75W
1.12W
85 110
Maximum Primary Power
Operating Ambient Temperature