VNH5019A-E datasheet
Table Of Contents
- 1 Block diagram and pin description
- 2 Electrical specifications
- Figure 3. Current and voltage conventions
- 2.1 Absolute maximum ratings
- 2.2 Thermal data
- 2.3 Electrical characteristics
- 2.4 Waveforms and truth table
- Table 11. Truth table in normal operating conditions
- Figure 4. Typical application circuit for DC to 20 kHz PWM operation with reverse battery protection (option A)
- Figure 5. Typical application circuit for DC to 20 kHz PWM operation with reverse battery protection (option B)
- Table 12. Truth table in fault conditions (detected on OUTA)
- Figure 6. Behavior in fault condition (how a fault can be cleared)
- Table 13. Electrical transient requirements (part 1)
- Table 14. Electrical transient requirements (part 2)
- Table 15. Electrical transient requirements (part 3)
- 2.5 Reverse battery protection
- Figure 7. Definition of the delay times measurement
- Figure 8. Definition of the low-side switching times
- Figure 9. Definition of the high-side switching times
- Figure 10. Definition of dynamic cross conduction current during a PWM operation
- Figure 11. Waveforms in full bridge operation (part 1)
- Figure 12. Waveforms in full bridge operation (part 2)
- Figure 13. Definition of delay response time of sense current
- Figure 14. Half-bridge configuration
- Figure 15. Multi-motors configuration
- 3 Package and PCB thermal data
- 3.1 MultiPowerSO-30 thermal data
- 4 Package and packing information
- 5 Order codes
- 6 Revision history
VNH5019A-E Electrical specifications
Doc ID 15701 Rev 7 17/34
Table 13. Electrical transient requirements (part 1)
ISO T/R
7637/1
Test Pulse
Test level
I II III IV Delay and impedance
1 -25 V -50 V -75 V -100 V 2 ms, 10 Ω
2 +25 V +50 V +75 V +100 V 0.2 ms, 10 Ω
3a -25 V -50 V -100 V -150 V 0.1 μs, 50 Ω
3b +25 V +50 V +75 V +100 V 0.1 μs, 50 Ω
4 -4 V -5 V -6 V -7 V 100 ms, 0.01 Ω
5 +26.5 V +46.5 V +66.5 V +86.5 V 400 ms, 2 Ω
Table 14. Electrical transient requirements (part 2)
ISO T/R
7637/1
Test Pulse
Test levels
IIIIIIIV
1C C C C
2C C C C
3a C C C C
3b C C C C
4C C C C
5C E E E
Table 15. Electrical transient requirements (part 3)
Class Contents
C
All functions of the device are performed as designed after exposure to
disturbance.
E
One or more functions of the device are not performed as designed after
exposure to disturbance and cannot be returned to proper operation without
replacing the device.