Instructions
Preparing for installation
  Switch the electricity supply, corresponding 
circuit breaker and/or automatic fuse OFF.
  Secure against unauthorized restart, e.g. by 
installing a warning sign.
  Check the power circuit for any remaining 
voltage using an appropriate testing device.
Installation 
  Read the information in section “Safety instructions”.
ø8 mm 
25 mm
•  Use the holes in the base mounting points (3) as a template to mark the mounting points.
•  Drill the mounting holes using a ø8 mm drill bit, to a depth of 25 mm. 
•  Insert anchors with an M6 inner thread into the hole, at the same level as the ground.
  Always use correct wiring technique! If in any doubt about how to correctly connect 
a cable, contact a specialist.
  Installation of the product must be carried out by a qualied professional (i.e. an 
electrician) who is familiar with all applicable regulations! Improper handling of 
mains voltage will endanger yourself and others!
•  Place the washers over the mounting screws (2).
•  Using the supplied hex key, attach the lamp to the ground.
OFF
These operating instructions  are  published by CEI Conrad  Electronic  International (HK) Limited,  18th  Floor, Tower 2, 
Nina Tower, No. 8 Yeung Uk Road, Tsuen Wan, New Territories, Hong Kong. All rights including translation reserved. 
Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic data processing systems require 
the prior written approval by the editor. Reprinting, also in part, is prohibited. The operating instructions reect the current 
technical specications at time of print.
© Copyright 2019 by CEI Conrad Electronic International (HK) Limited  *1763881_v2_0419_02_dh_m_en
  Turn the corresponding circuit breaker and/
or automatic fuse back ON.
•  If the light switch is on and the lamp does not light up, 
turn OFF power to the circuit immediately.
•  Turn OFF the circuit breaker and/or automatic fuse.
•  Check the connection to the power circuit.
Care and Cleaning
•  Turn the  mains  voltage  to  the  light  OFF  (or  disconnect  it  from  the  mains)  and  allow  to 
sufciently cool down.
•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may 
damage the casing or cause the product to malfunction.
•  Use a dry, lint-free cloth to clean the product. To remove stubborn dirt, moisten the cloth 
slightly with water.
•  This product has an IP65 rating and can be sprayed clean using a fresh water hose.
•  Never point a water jet, for example such of high-pressure cleaning equipment, at the lamp, 
as that could damage the seals!
•  Do not wear metallic or conductive jewelry such as necklaces, bracelets or rings when 
carrying out maintenance work on the product (including cleaning).
Disposal
  Electronic devices are recyclable waste and must not be disposed of in the 
household waste. At the end of its service life, dispose of the product in accordance 
with applicable regulatory guidelines.
You thus fulll your statutory obligations and contribute to the protection of the environment.
Technical Data
Operating voltage ......................... 220 – 240 V/AC, 50 Hz
Power consumption ...................... Max. 10 W
Protection class ............................ I
Protection type .............................. IP65
Mounting location ......................... outdoors
Illuminant ...................................... 36 LEDs
Dimmable ..................................... No
Colour temperature ....................... 3000 K (warm-white)
Luminous ux ............................... 280 lm
Operating/storage conditions ........ -20 to +70 °C, 0 – 100 % RH
Power cable type .......................... H05 RN-F3-1.0 mm
2
 wire.
Power cable length ....................... 100 cm (from lamp unit)
Dimensions (L x W x H) ................ 130 x 110 x 1000 mm
Weight .......................................... 2340 g
ON
Distributed by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau