Owner's Manual
Page 4
English
2
1
UWF
Quick Disconnect
Pressure Relief Valve
Dedicated
Return Line
Restrictor Disk
Leader Hose Floats
2-3' apart
Return
Line
Feed Hose Floats
1.5 to 3' apart
Center
Swivel
In-Line
Filter
Leader Hose
Length = Max. Depth
Return
Line
Furthest
Point
Leader Hose Floats
2-3' apart
UWF®
Feed Hose Floats
1.5 to 3' apart
Center
Swivel
In-Line
Filter
Leader Hose
Length = Max. Depth
®
Install the Universal Wall Fitting
1. Turn on the filtration pump and flush out the plumbing line.Turn pump off.
2. Remove the Universal Wall Fitting (UWF
®
) from the Quick Disconnect and screw it
into the return opening with the blue restrictor disk in place.
3. Turn the Quick Disconnect clockwise into the UWF
®
and pull away to secure. The Quick
Disconnect will click into place.
Adjust Feed Hose To Fit Pool Length
1. Measure the deepest part of the pool. Cut leader hose from the end that attaches to the
feed hose (away from the back up valve) so length is equal to the greatest depth of the
pool.
2. Attach leader hose to feed hose and connect hose to the pool wall at the return line.
Extend hose to farthest point of pool. The hose end must be within 6 inches – longer or
shorter – of the farthest point. See diagram below.
If hose is too long: Separate hose at center swivel. Cut half of the overage from each
10-foot feed hose section that attaches to the center swivel.
If hose is too short: Add a feed hose section (part #9-100-3104), a swivel (part #D20)
and two (2) hose nuts (part #D15). Adjust to proper length.
Each feed hose section should be equal in length after adjustments.
3. After adjusting the length, position the hose floats as shown.
Quick Installation Instructions