Owner's manual

ROLLSEAL, INC. • 1751 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-7000 • Fax 256-287-7010
Manual No. 4801-5202 rev 4-03 Page 3 of 4
Directions For Dual Speed Control (6607-8072)
Disconnect all electrical power.
Open the top cover.
Remove two or three of the evaporative pads on the left of the unit to allow access to the
existing control box.
Make sure all electrical power is
disconnected!
Open the existing control box at the top of
the interior of the PolarCool cabinet.
Cut the incoming power cord (two
conductor plus ground) inside the existing
control box.
Completely remove the existing power
cord from the PolarCool cabinet.
Run the new 5-conductor cable from the
existing control box in the PolarCool
cabinet, through the cable connector, into
the External Control Box.
Disconnect the wires from switches in the
existing control box. Connect wires as
shown in diagram at lower left.
NOTE: The existing switches may be left
in place, however, if removed, the holes
should be plugged.
1
2
PolarCool Cabinet
External Control Box
(Dual Speed)
PUMP CONTROL
3
NOTE: Since the
existing power cord
is to be reused,
carefully follow Step
2 so as not to
damage or cut the
power cord during
removal from the
cabinet!
New Wiring Of PolarCool Existing Control Box
For Dual-Speed Control