Owner's manual

ROLLSEAL, INC. • 1751 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-7000 • Fax 256-287-7010
Manual No. 4801-5202 rev 4-03 Page 2 of 4
Run the new 4-conductor cable from the
existing control box in the PolarCool
cabinet, through the cable connector, into
the External Control Box.
Disconnect the wires from switches (or
circuit board if converting a variable speed
unit) in the existing control box. Connect
wires as shown in diagram at right.
NOTE: The existing switches may be left in place,
however, if removed, the holes should be
plugged.
NOTE: If using an External Control Box with a
Variable-Speed PolarCool, the PolarCool
will function as a single speed.
Tie the 4-conductor, pump and motor
cables to the cabinet to prevent movement
of the cable during operation.
Replace the evaporative pads removed in
Step 1 and secure the top of the
PolarCool cabinet.
Mount the External Control Box in the
desired location taking into account the
distance between the External Control
Box and the PolarCool cabinet must be
reached with the supplied 4-conductor
cable.
In the External Control Box connect the 4-
conductor cable to the lugs as shown in
diagram below. Then connect the power
cord removed in Step 2 to the lugs as
shown. Check the power cord for
abrasions or cuts. Discard and replace if
necessary.
Installation of Single-Speed External
Control (6607-8071) complete.
3
5
6
8
7
New Wiring Of PolarCool Existing Control Box
For Single Speed Control
PolarCool External Control Box
Single-Speed Connections
4